5.4 Final Assembly
1. Mount the cover by aligning the two studs near the rear of the
cover with the openings of the z-shaped slots in the top panel.
Slide the cover to the rear, then upward and finally to the rear
again. See figure 11.
Figure 11: Installing the Cover
2. Inspect the alignment of the camera / lens in the unit. The cam-
era / lens should be placed as close to the viewing window as
possible. Remove the cover and make adjustments as needed and
then replace the cover.
3. Secure the cover by turning either the tamper-resistant screw
(using the drive tool supplied) or the keyed lock (using the key
supplied) counter-clockwise until the cover is in tight contact with
the top panel.
Note: Save the drive tool or the key for future use.
4.
For installations where the unit is mounted to the ceiling, the top
cover may be hinged open for servicing or adjusting the camera /
lens. Simply allow the two studs in the rear of the cover to rest in
the bottom of the z-slots in the top panel.
WARNING!
– Do not use the hinge feature when the unit is
mounted to a wall, the cover may fall from the top panel.
Figure 12: Cover Hinged Open