background image

5.8

Power Connection

5.8.1 Power Connection 

HS9383S 

1.

Pull the wires through the conduit fitting and make sure
that the threaded section of the fitting mates up with the
threads in the rear cap.

2.

Pull the wires through the threaded hole in the rear cap
of the cradle. 

3.

A screw, nut and terminal lug are provided for the safety
ground. 

4.

Unscrew the terminal lug and attach the ground wire.
Attach the lug back to the rail of the cradle. 

5.

Connect the power wires to the camera per instructions
provided with the camera.

5

Spacer

Washer

1/4 - 20 Screw

Spacer

Washer

1/4 - 20 Screw

Figure 3: Mounting a Fixed Lens Camera

Figure 4: Mounting a Zoom Lens Camera

WARNING: 

Only use the cables specified under

INSTALLATION, Cable Requirements  for wiring of

all cameras and lenses.

Crad

le

Terminal Lug 

Threaded Hole 

Rear Cap 

Cradle Rail

Figure 5: Power Connection

Z

Zo

oo

om

m  L

Le

en

nss  C

Ca

am

me

erra

ass::

Allow 

3

/

16

-inch (5 mm) clearance

from the front face of the lens to the front faceplate of the
cradle during the camera/lens assembly. This clearance
provides the necessary space for the lens to extend
outward when zooming. Secure both the camera and the
lens to the cradle with the

1

-20 BHCS and appropriate

plastic spacer. See 

Figure 4.

5.8.2 Power Connection 

HS9383-2H

1.

Pull the wires through the conduit fitting and make sure
that the threaded section of the fitting mates up with the
threads in the rear cap.

2.

Pull the power wires through the threaded hole in the
rear cap of the cradle. 

3.

A screw, nut and terminal lug are provided for the safety
ground. See 

Figure 5

.

5.7 

Video Cable Connection 

1. Pull the video cable through the conduit fitting and make

sure that the threaded section of the fitting mates up
with the threads on the rear cap.

2. Pull the video cable through the threaded hole in the rear

cap of the cradle.

3. Connect the video cable to the camera.
4.  If using a zoom lens, pull the lens cable through the

conduit fitting and attach to the zoom lens pursuant to
the manual supplied with that product. 

4.

Unscrew the terminal lug and attach it to the ground
wire. Attach the lug back to the rail of the cradle.

5.

Install the power wires by using the gray connectors
provided. Push and hold the side of the connector that
does not have wires in it. Slide the tip of the wire into
the opening of the connector until it stops then release.
Repeat this same operation for the other connector. See

Figure 5

.

6.

Connect the camera to the black and white wires per the
instructions provided with your camera. 

Gray
Connectors

Insert wire

Insert wire

Figure 6: Wire Connectors

Summary of Contents for HS9383S Series

Page 1: ...aining ring Cradle Terminal Lug Threaded Hole Rear Cap Cradle Rail Stainless Steel Dust Proof Housing HS9383S SERIES I N S T A L L A T I O N A N D O P E R A T I N G I N S T R U C T I O N S W W W A I G...

Page 2: ...result in a fire or electric shock Never spill liquid of any kind on the unit 15 Servicing Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltag...

Page 3: ...inch BHCS Button Head Cap Screw 1 1 4 20 x 3 4 inch BHCS Button Head Cap Screw 1 0 4 mm 0 016 in Plastic Spacer 1 1 65mm 0 292 in Plastic Spacer 1 3 9 mm 0 154 in Plastic Spacer 1 7 4 mm 0 292 in Pla...

Page 4: ...ype H05RN F3G0 75 and H05RN F3G1 00 Cable Size Outside diameter between 4 3 mm 0 170 in 11 9 mm 0 470 in Cable Shape Round Conductors 3 conductor version and 2 conductor version Agency Rating VDE Envi...

Page 5: ...S and appropriate plastic spacer See Figure 4 5 8 2 Power Connection HS9383 2H 1 Pull the wires through the conduit fitting and make sure that the threaded section of the fitting mates up with the thr...

Page 6: ...of the housing stop pushing when the rear cap of the cradle is touching the o ring in the rear of the housing 2 Insert the tip of a flat head screwdriver in the slot of the housing lay the screwdriver...

Page 7: ...lded to a steel backer plate Each stud must have a minimum pull out strength of 200 kg 450 lb d If the wall mount is attached to wood or to a blind structure with no access to the rear each fastener m...

Page 8: ...2005 Aigis Mechtronics 1124 Louise Road Winston Salem NC 27107 5450 Tel 336 785 7740 Fax 336 785 7744 Data subject to change without notice 100 0132 003 AIG 01 07 Printed in U S A...

Reviews: