IMPULSE SEALER INSTRUCTIONS
(For Portable Operation of AIE 305 A1 Sealer)
Please read entire sheet before starting.
Set up
1.
Remove sealer from case. Set case lid in supported, sloped position. Install shelf on front of
case/stand. Place sealer on stand. If a stand is not provided, place sealer on a sturdy box,
with lower sealer jaw 8
2
" above table. Connect switch line to sealer back and place
switch on floor.
2.
Set dials:
Recycle
to 2,
Congealing
to 6,
Sealing
to 4, and
Action Selector
switch to
Manual.
3.
Turn
Power
switch on. (Do not allow small children in area when sealer is on.)
4.
Cut open top of bag containing oxygen absorbers. Remove only enough packets for the next
30 minutes. Reseal bag with impulse sealer. Reopen and reseal bag, as additional absorbers
are needed.
Filling pouches
5.
Fill pouch with one
level
gallon of product. Overfilling will result in poor seams.
6.
Place an oxygen absorber packet on top of product in pouch.
7.
Wipe product dust from inside seal area using a dry towel. (Powdered products)
Sealing pouches
8.
Place pouch, in an upright position, in front of sealer.
9.
Close pouch opening by grasping side seams and pulling outward.
Bend top
1
2
" of pouch
over at a right angle to evacuate air out of headspace, settle product, and flatten top.
10. Hold pouch by side seams and insert pouch top into jaw opening (
keep fingers clear of
jaw)
.
11. Position pouch to seal near top. Stretch outward on side seams to
remove wrinkles
and
press foot switch. Remove pouch when cycle is completed.
Testing seals
12. Visually inspect seams for complete seals and absence of burned spots.
13. Check to see if seam can be pulled apart. Push on pouch to see if air or product can be
forced out.
14. If seams pull apart, check for inadequate cleaning of seam area or overfill. If necessary,
increase sealing setting by 1/4 step. (Example: From 4 to 4.25) Verify that congealing
setting is at 6.
15. If seams are burned, decrease sealing setting 1/4 step.