4.2 BED EXTENSION

The integrated bed extension can add an extra 200mm of length  

to the mattress platform.

MOVING BED EXTENSION FROM CLOSED/STANDARD  

BED POSITION

1.  The bed extension is held in position by two threaded hand wheels  

on either side of the bed. Unscrew (anti clockwise) the hand wheels on 

both sides. It is not necessary to remove the hand wheels completely, 

unscrewing them by approximately 10mm of thread length will allow for 

the internal lock nut to travel freely past the thread of the hand wheel.

2.  With both hand wheels now unscrewed, gently pull with an even  

force on both sides of the bed end. (2) Indicates the best position for  

easier extension if used on both sides of the panel at the same time.

3.  Lock hand wheels in place on either side to lock bed end in.

4. Return the hand wheels back to their locked position (1) 
To reposition the bed end back to the closed/standard bed position 

use the same technique as above.

1

2

WARNING: The bed extension is designed for use as a bed extension  

only and is not meant to support the body weight of a person sitting.  

The extra length of the bed with extra load can also make the bed 

unstable potentially resulting in injury to the user and patient.

4.3 FOLD DOWN SIDE RAILS (OPTIONAL)

Bed rails (optional) are easily fitted by clamping to the bed frame. 

When fitted correctly, AC4 bed rails meet the requirements of Medical 

equipment international standard IEC 60601-2-52, which includes specific 

rail requirements.

4.3.1 FITTING THE SIDE RAILS

NOTE: The rails are a left and right hand set and when fitted correctly fold 

down towards the foot end of the bed.

1.  Before fitting the rails unscrew the hand wheel to bring the locking 

clamp into an open neutral position which will allow the rail to fit over 

the side rail of the bed.

    

 Closed Position  

  

Open Position

2.  With both hand wheels now unscrewed, lift the rail into position. It 

is important that the rails are fitted to a specific position on the bed, 

which is indicated by the bolt on top of the bed frame. Position the  

rail over the bolt and tighten the hand wheel to the closed position.

Summary of Contents for AC4 BED Single

Page 1: ...AC4 BED Single King Single USER MANUAL...

Page 2: ...pecifications 14 6 Cleaning 15 7 Maintenance 15 8 Transportation and Storage 17 9 Accessories 17 10 Warranty and Service 18 Thank you for choosing this Aidacare AC4 Bed This product has been specifica...

Page 3: ...perate the bed and its accessories It is recommended that the User Manual be kept in an easily accessible place for quick reference If required Aidacare product specialists can provide additional trai...

Page 4: ...arts of the bed DO NOT place the handset or power cord across the mattress surface of the bed when the bed is not connected to mains power Always store the power cord within the power cord fixtures fi...

Page 5: ...et cord to manoeuvre the bed Always apply the brakes when the bed is in a stationary position 3 1 HANDSET BUTTON OPERATION AC4 beds are powered by three electric actuators which are controlled by the...

Page 6: ...1 2 WARNING The bed extension is designed for use as a bed extension only and is not meant to support the body weight of a person sitting The extra length of the bed with extra load can also make the...

Page 7: ...3 3 SIDE RAIL SAFETY LOCK INDICATOR The side rail locating pin has a yellow coating that allows for visual inspection of the locking device When the side rail is in the raised position viewing the re...

Page 8: ...owing procedure also applies to the beds accessories but does not include mattresses Wipe the beds surfaces with a soft cloth moistened with hot water and mild detergent or the facilities recommended...

Page 9: ...is not fully effective 2 Check the two steering lock castors for correct operation 3 If either the brakes or the steering locks are not working correctly contact an approved service agent Side Rails i...

Page 10: ...ge at aidacare com au All warranty matters should be directed to Aidacare Customer Service on 1300 133 120 Aidacare does not warrant against excessive or incorrect use modification or any situation th...

Page 11: ...ABUM18 10 050822 AIDACARE PTY LTD Building 3A 1 Moorebank Avenue Moorebank NSW Australia 2170 1300 133 120 aspirecare com au MADE IN PRC...

Reviews: