3�6 SES Inband Features
To ensure J3016-01 can work properly and provide high performance, durability. J3016-
01 has implemented SCSI Enclosure Services to monitor the status of power supply,
system cooling fan and working temperature. It also has the indicators to deliver the
status of fail devices such as power supply or cooling fan. You can get the information
directly from the front indicators to know how your enclosure works.
For detailed information, please visit
http://www.t10.org
If you are a member of the T10 working group, the Standard which controlled by T10
technical committee, could be found at
http://www.t10.org/cgi-bin/ac.pl?t=f&f=ses2r19a.pdf
3.6.1 SES pages supported are listed below
00h - List of supported diagnostic pages
01h - SES configuration
02h - SES enclosure control / enclosure status
04h – SES String In
05h – SES Threshold Out / In
07h - SES element descriptor
0Ah - SES additional element
0Eh - SES download microcode control / SES download microcode
status
82h – SES Vendor specific page : Chassis Number
83h – SES Vendor specific page : Canister Number
3.6.2 SES elements supported are listed below.
02h - Power Supply
03h – Cooling
04h - Temperature Sensor
0Eh - Enclosure
12h - Voltage
17h - Array Device