34
Chapter 3. Sub-system Configuration Setup
J4060-03 User Manual
3.5.7 How to configure wide port checker
This feature is applicable for SAS drives instead of SATA drives. If there is no connection
with any active SAS initiator by checking all wide ports, AIC Expander Controller stops all
attached SAS drives to save power consumption of SAS drives. Otherwise, AIC Expander
Controller starts all attached SAS drives to provide drive access service to any active SAS
initiator. The same setting should be applied to HUB and EGDE.
(A) Get the current state of wide port checker
cmd> check_wide_port
Checking wide port is OFF
(B) Enable checking wide port. The new setting will take effect after reset.
cmd> check_wide_port on
cmd> reset
(C) Disable checking wide port. The new setting will take effect after reset.
cmd> check_wide_port off
cmd> reset