background image

   +49 2173 -164-0   |      [email protected]

10

11

WWW.AHB-SHOP.COM 

 

SOL

UT

IONS

SOL

UT

IONS

  

INSTRUCTION MANUAL 

INSTRUCTION MANUAL 

Power-on test:
connect the input power supply and the backlight is on; 

the clamp is not connected, the clamp is positive, but the 

terminal voltage of the clamp is lower than 0.5V, and the 

clamp is flashing.

Reverse connect detection:
when the clamp is reverse connected, the reverse connect 

symbol flashes.

Wrong connect detection:
the voltage at both ends of the clip is higher than 0.5V, after 

selecting, the voltage gear according to the gear selection 

key, waiting for 5S, when the positive voltage of the clip 

is greater than 7.8V (6V mode),15.6V (12V mode), the clip 

symbol flashes.

Bad battery detection:
charge the 6V battery, if the voltage is less than 5.5V ±0.2v 

in 4 minutes or the current does not reach 1A after 2 hours 

of high voltage de-vulcanization, the bad battery symbol 

flashes. Charge the 12V battery, if the voltage is less than 11V 

±0.2v in 4 minutes or the current does not reach 2A after 

2 hours of high voltage de-vulcanization, the bad battery 

symbol flashes.
High voltage de-vulcanization: 
6 V: before charging, the voltage is less than 6.2 V and filled 

within 5 minutes, into high voltage de-vulcanization, 7.9V 

high voltage charging. When the current is greater than 1A, 

charge normally.

12V: before charging, the voltage is less than 12.4V and filled 

within 5 minutes, into high voltage de-vulcanization, at 15.8V 

high voltage charging. When the current is greater than 2A, 

charge normally.

Constant current charging:

Full charge detection:
6VSTD, voltage 7.2 ±0.2v, current 0.6±0.3a, stop charge, the 

Lcd screen show “FUL”
6VSTDSNOW, voltage 7.4±0.2v, current 0.6±0.3a, stop charge, 

the lcd screen show “FUL”
12VSTD, voltage 14.4±0.2v, current 0.6±0.3a, stop charge, the 

lcd screen show “FUL”
12VSTDSNOW, voltage 14.9±0.2v, current 0.6±0.3a, stop 

charge, the lcd screen show “FUL”
12VAGM, voltage 14.7±0.2, current 0.6±0.3a, stop charge, the 

lcd screen show “FUL”
12VAGMSNOW, voltage 15.2±0.2v, current 0.6±0.3a, stop 

charge, the lcd screen show “FUL”

Battery voltage

6V-6.8V

6.8V-7V

Above 7V

6V mode

2A

1.5A

Lower than 1A

Battery voltage

12V—13.6V

13.6V—14V

Above 14V

12V mode

4A

3A

Lower than 2A

Summary of Contents for 329100370

Page 1: ...Best Nr 329100370 WWW AHB SHOP COM Batterieladeger t 6V 2A 12V 4A 11 stufig Battery charger 6V 2A 12V 4A 11 stages...

Page 2: ...d des Aufladens k nnte explosives Gas entstehen bitte vermeiden Sie Funken Batteries ure kann Ihnen schaden sollten Sie mit Batter ies ure in Kontakt kommen suchen Sie bitte einen Arzt auf Das Ladeger...

Page 3: ...f r eine schlechte defekte Batterie Laden Sie eine 12V Batterie und die Spannung bleibt innerhalb von 4 Minuten unter 11V 0 2V oder nach 2 Stunden erreicht der Strom nicht 2A blinkt das Symbol f r ein...

Page 4: ...den Vollzustand ber 12V Modus Wenn die Batterie innerhalb von 2 Minuten weniger als 12 8 V voll ist bestimmt das Ladeger t dass der Pulsreparaturzustand 2 Stunden lang mit einem Hochspan nungspuls von...

Page 5: ...you if you should have contact with battery acid go immediately to a doctor The charger is not suitable for children or people who can t read and understand the safety instructions Store it out of th...

Page 6: ...does not reach 2A after 2 hours of high voltage de vulcanization the bad battery symbol flashes High voltage de vulcanization 6 V before charging the voltage is less than 6 2 V and filled within 5 mi...

Page 7: ...hours and then enters the full state 12V mode When the battery is full of 2 minutes less than 12 8 V the charger determines that the pulse repair state is charged for 2 hours with a high voltage pulse...

Page 8: ...SOLUTIONS SOLUTIONS SOLUTIONS SOLUTIONS RHEINPARKALLEE 9 D 40789 MONHEIM AM RHEIN 49 2173 164 0 FREE FAX 0800 2 42 32 93 INFO AHB INTERNATIONAL COM WWW AHB SHOP COM...

Reviews: