Positioning and assembly of pulleys and cables: 

 
In  order  for  the  activation  and  deactivation  system  to  operate  correctly  from  outside  the  pit,  it  is  very 
important  that  the  cables  are  properly  guided  into  position.  Pulleys  are  provided  with  the  cables  for  this 
purpose.  The  role  of  these  pulleys  is  to  guide  the  insertion  of  the  cables  to  avoid  excessive  angles  or 
entrapment. The image shows how to position these pulleys. 
 
Pulleys 1 and 2 are placed on the floor of the pit to align the 
cable with the opening mechanism. 
 
Pulley 3 is placed on the pit to guide the insertion of the cable 
through the holes on the buffer support, to ensure they enter 
smoothly. 
 
Once the cables have been fed through correctly, the ends are 
drawn up to the mouth of the pit (elevator door) and secured 
with  a  ring  clamp  so  that  they  can  be  grasped  from  outside 
the pit. 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

PULLEY 3 

PULLEY 2 

PULLEY 1 

(Regulation 35-49)

 

(Regulation 50-80)

 

Cable aligned 
horizontally 

Summary of Contents for OKATT DNP16-01

Page 1: ...AGUI cannot accept liability for any damage caused by incorrect handling or as the result of action other than that indicated in this manual The product guarantee may be rendered invalid if used inco...

Page 2: ...a selection of chocks between the buffer support and the wall and 35 80 continuous mm regulation through the use of fixtures VERTICAL BUFFER SUPPORT KIT VERTICAL BUFFER SUPPORT BAG OF ACCESSORIES The...

Page 3: ...l fixture There are three possible situations Direct The buffer support is mounted directly onto the wall With chocks When the distance to the wall is between 5 30 5 mm intervals With L fixtures When...

Page 4: ...o adjust how the plate lies against the buffer The image shows the assembly position for the supports Regulation of lateral supports It is very important that when the buffer support is not activated...

Page 5: ...ufacturer s directions for proper installation It is essential to observe the torque value which will vary depending on model and manufacturer Plumbing and fixing the buffer support Reposition the buf...

Page 6: ...is to guide the insertion of the cables to avoid excessive angles or entrapment The image shows how to position these pulleys Pulleys 1 and 2 are placed on the floor of the pit to align the cable with...

Page 7: ...g them at the exact length required to prevent any excess loose cables inside the pit The green cable can be shortened from the handle but loosening the set screw and sliding it until the cable is at...

Page 8: ...d to the electricity supply following the indications on the diagrams Right side Monitors the active buffer support position Left side Monitors the resting buffer support position Check operation Once...

Page 9: ...ems with reduced headroom the maintenance technician must first open the door of the lowest floor and activate the vertical buffer support The mechanism is activated and deactivated from floor level w...

Reviews: