8
HOW TO USE YOUR SPREADER
SETTING THE FLOW CONTROL
(Refer to figure 13 on page 7.)
1.
Loosen the nylon wing nut, set the adjustable stop to
the desired flow rate setting and retighten the wing nut.
The higher the setting number, the wider the opening
in the bottom of the hopper.
2.
Refer to the application chart on page 8 and to the
instructions on the fertilizer bag to select the proper
flow rate setting.
3.
Pull the flow control arm against the adjustable stop
for the on position and toward the hopper for the off
position.
OPERATION
USING YOUR SPREADER
We do not recommend the use of any powdered lawn
chemicals, due to difficulty in obtaining a satisfactory or
consistent broadcast pattern.
1.
Determine approximate square footage of area to be
covered and estimate amount of material required.
2.
Before filling the hopper make sure the flow control arm
is in the off position and the closure plate is shut.
3.
Break up any lumpy fertilizer as you fill the hopper.
4.
Set the adjustable stop with the flow control arm still
in the off position. Refer to the application chart on
this page and to the instructions on the fertilizer bag
to select the proper flow rate setting.
5.
The application chart is calculated for light to heavy
application at a walking speed of 3 mph, or 100 ft. in 23
seconds. A variation in speed will require an adjustment
of the flow rate to maintain the same coverage. The
faster you walk, the wider the broadcast width.
6.
Always start the spreader in motion before opening
the closure plate.
7.
Always shut the closure plate before turning or stopping
the spreader.
8.
If fertilizer is accidentally deposited too heavily in a
small area, soak the area thoroughly with a garden
hose or sprinkler to prevent burning of the lawn.
9.
To insure uniform coverage, make each pass so that the
broadcast pattern slightly overlaps the pattern from the
previous pass as shown in figure 14. The approximate
broadcast widths for different materials are shown in
the application chart on this page.
10. When broadcasting weed control fertilizers, make sure
the broadcast pattern does not hit evergreen trees,
flowers or shrubs.
11. Heavy moisture conditions may require a cover over the
hopper to keep contents dry. The vinyl cover (available
as an accessory) acts as a wind and moisture shield,
but should not be used as a rain cover. Refer to the
parts list on page 11.
FIGURE 14
APPLICATION DIAGRAM
OVERLAP
8' to
10'
OPERATING SPEED
- 3 MPH. (100 ft. in 23 seconds)
IMPORTANT:
Application rates shown in the chart are af-
fected by humidity and by the moisture content of the material
(granular and pellet). Some minor setting adjustments may
be necessary to compensate for this condition.
APPLICATION CHART
MATERIAL
TYPE
FLOW SETTING
SPREAD
WIDTH
FERTILIZER
Powder
3 - 5
3' - 4'
Granular
3 - 5
8' - 10'
Pelleted
3 - 5
10' - 12'
Organic
6 - 8
6' - 8'
GRASS SEED
Fine
3 - 4
6' - 7'
Coarse
4 - 5
8' - 9'
ICE MELTER
6 - 8
10' - 12'