To carry out moisture measurements, proceed as follows:
To carry out moisture measurements, proceed as follows:
To carry out moisture measurements, proceed as follows:
To carry out moisture measurements, proceed as follows:
Penetrate the probe on one of the side surfaces of the bale.
With the current display you can already read the measured value during
the slow penetrating. When pulling out the lance, the values are not
meaningful.
Moisture values are displayed between 9 and 50 %.
Moisture values below 9 % are displayed as „L“.
At moisture values over 50 the display flashes with the message „H“.
Repeat the measurement at different places in the bale to obtain a better
overview of the situation in bales.
The display lighting turns on automatically when making measurements
with moisture above 12 %. To enable it manually press the [moisture] or
[temperature] key. After 10 seconds without pressing a button and
without measurements above 12 % the light is turned off.
After 2 minutes without pressing a button and without measurements
above 12 % the unit switches off completely. To turn on again, press the
[moisture] or [temperature] key.
If a battery sign appears on the display, the battery voltage is below 8
volts and the battery should be replaced.
To carry out temperature measurements, proceed as follows:
To carry out temperature measurements, proceed as follows:
To carry out temperature measurements, proceed as follows:
To carry out temperature measurements, proceed as follows:
Insert the probe on one of the side surfaces of the bale and read the
display.
Wait until the temperature is stable, it can take up to several minutes.
Read the value only, when the display shows a steady value.
Note that the lance can warm up itself by repeatedly piercing. Allow it to
cool down before you make further measurements.
Repeat the measurement at different places in the bale to obtain a better
overview of the situation in bales.
To switch the unit between Celsius and Fahrenheit hold down the
[Temperature] key for 5 seconds. The setting Celsius is indicated on the