background image

6

 

Total Extension                      

 Cord Size (AWG)

 Cord Length (feet)  

 

                    

                   25  

 

   16

 

50 

 

   12

 

100 

 

   10

 

150 

 

     8

 

200 

 

     6 

UNPACKING

Carefully remove the tool and all loose items from 
the shipping container. Retain all packing materials 
until after you have inspected and satisfactorily 
operated the machine.
 

NOTE: An appropriate  diamond blade must be 
mounted to the machine before operating. 
R e f e r   t o   t h e   s e c t i o n   o f   t h i s   m a n u a l : 
“INSTALLING THE BLADE” 

CARTON CONTENTS

Stone Cutting Circular Saw Machine
*   Vacuum hose connector
*   Parallel guide
*   Quick-release water hose coupling
*   L-hex wrench

DO NOT OPERATE THIS TOOL UNTIL YOU READ 
AND UNDERSTAND THE ENTIRE INSTRUCTION 
MANUAL.

  

dust absorption system and wear a suitable 
dust protection  mask and remove deposited 
dust with a vacuum cleaner.

ELECTRICAL CONNECTION

The network voltage must conform to the voltage 
indicated on the tool name plate. Under no 
circumstances should the tool be used when the 
power supply cable is damaged. A damaged cable 
must be replaced immediately by an authorized 
Customer Service Center. Do not try to repair the 
damaged cable yourself. The use of damaged 
power cables can lead to an electric shock.

INTENDED USE

This saw is designed exclusively for wet or dry 
cutting of stone, concrete and masonry. This 
machine should not be used for cutting other 
materials. The machine should not be converted or 
modified, e.g. for any other form of use, other than 
as specified in these operating instructions. The 
user shall be liable for damages and accidents due 
to incorrect use.

EXTENSION CABLE

If an extension cable is required, it must have a 
sufficient cross-section so as to prevent an 
excessive drop in voltage or overheating. An 
excessive drop in  voltage reduces the output and 
can lead to failure of the motor. The following table 
shows you the correct cable diameter as a function 
of the cable length for this machine. Use only U.L. 
and CSA listed extension cables. Never use two 
extension cables together. Instead, use one long 
one.

Summary of Contents for SCS7

Page 1: ...ng SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CAUTION For tools equipped with overload protection when the motor shuts off due to overload always run the machine with no load for at least 3 minutes to reduce temperature before returning to operation to avoid burn out of the motor Version 20140122 ...

Page 2: ... 7 8 Max Blade Diameter 180mm Max Cutting Depth 55mm Weight 6 7kg 14 74Lbs Fig 1 Main handle Water Valve Secondary handle Arbor Bolt Sighting notches Spindle Lock Aluminum Guide Rails Quick release water hose coupling Vacuum Port Cap Brush Cap Depth Scale On Off triggerswitch Depth Stop Lever Release Button ...

Page 3: ... When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock f If operating a power tool in a damp location is unavoidable use an earth leakage circuit breaker Use of an earth leakage circuit breaker reduces the risk of electric shock 3 PERSONAL SAFETY a a Stay alert watch what you are doing and use c...

Page 4: ...ged have the power tool repaired before use Many accidents are caused by poorly maintained power tools f Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tool accessories and tool bits etc in accordance with these instructions taking into account the working conditions and the work to be ...

Page 5: ...kpiece against the blade 13 Allow the motor to achieve full speed before cutting 14 Important After completing the cut release power switch and wait for coasting blade to stop completely before putting the saw down 15 Never operate the tool in an area with flammable solids liquids or gases Sparks from the commutator carbon brushes could cause a fire or explosion 16 There are certain applications f...

Page 6: ...es should the tool be used when the power supply cable is damaged A damaged cable must be replaced immediately by an authorized Customer Service Center Do not try to repair the damaged cable yourself The use of damaged power cables can lead to an electric shock INTENDED USE This saw is designed exclusively for wet or dry cutting of stone concrete and masonry This machine should not be used for cut...

Page 7: ...and that are rated for the machine s maximum rated speed or higher REMOVING THE BLADE DISCONNECT TOOL FROM POWER SOURCE Removal is the opposite of installing the blade TO ADJUST DEPTH OF CUT DISCONNECT TOOL FROM POWER SOURCE TO ADJUST THE DEPTH OF CUT Loosen the Depth Stop Lever by pushing it forwards and adjust the depth of cut to the desired amount Then retighten the Depth Stop Lever See Fig 3 H...

Page 8: ...heck all connections of the water feed system to ensure there are no leaks Inspect hoses and other critical parts which could deteriorate WARNING If you detect a leak in any part of the water supply system shut the machine down immediately and repair the fault WARNING The maximum water pressure should not exceed 70 psi 4 bar The water feed system allows the machine to cut more effectively Ensure t...

Page 9: ...ate for a time take care that parts of your body do not come into contact with the blade while it is still rotating ELECTRONIC OVERLOAD PROTECTION If while cutting the machine reaches a load approaching overload level the electronic overload protection will kick in and shut the saw off When this happens release the trigger and return the machine to its topmost position out of the cut and wait at l...

Page 10: ...rious injury CAUTION Keep the cord away from cutting area to prevent it from becoming entangled in the workpiece Do not force the cut Let the saw do the cutting at the rate of speed permitted by the type of cut and workpiece S H A R P E N I N G D U L L D I A M O N D BLADES If a lot of sparks are seen while cutting this is a sign that the blade is becoming dull To create better diamond exposure sha...

Page 11: ...ign properly and slide freely Then replace the brush caps See fig 10 If the replacement of the power supply cord is necessary this has to be done by the manufacturer or their agent in order to avoid a safety hazard WARNING All repairs must be entrusted to an authorized service center Incorrectly performed repairs could lead to injury or death Fig 10 Brush Cap ...

Page 12: ...12 ...

Page 13: ...13 WIRING ...

Page 14: ... 46 45 48 16 44 45 56 55 54 50 52 NO 01 79 V1 8 32 26 29 30 28 28 31 01 02 03 04 05 06 07 08 10 11 12 13 14 15 16 17 46 47 49 53 54 51 18 19 27 09 79 20 21 25 73 72 62 72 62 TO52 TO60 TO60 TO45 TO45 TO75 75 76 77 62 42 T0 40 T0 52 60 T0 75 T0 40 32 71 78 23 22 24 ...

Page 15: ...1 PARALLEL GUIDE 1 32 THUMB KNOB M5 4 33 BALL BEARING 6002LLU 1 34 SPINDLE LOCK 1 35 FAN SHROUD 1 36 ARMATURE M1 25 x 8T 1 37 BALL BEARING 6002LLU 1 NO Parts Name Q TY 38 WAVE SPRINGWASHER 1 39 STATOR SCREW M5 60 2 40 STATOR 1 41 MOTOR HOUSING 1 42 FLATWASHER Ø5 Ø12 1 1 43 SCREW M5 30 1 44 SCREW M5 50 2 45 BRUSH HOLDER 7 11 2 46 CARBON BRUSH 7 17 17 2 47 BRUSH CAP 7 11 2 48 SCREW M5 20 1 49 AUX HA...

Page 16: ......

Reviews: