11
TROUBLESHOOTING GUIDE
PROBLEM CAUSE
REMEDY
No propane gas at burner
Check that the gas tank valve is open.
Turn the control knob to “ON” and push
the control knob in. Make sure tank has
propane gas.
No spark at electrode
Check that the AA battery is installed
with the negative (-) end first and has a
charge. Check that the wire is
connected to the ignition module.
Check that the electrode is not cracked
or broken.
Burner Won’t Light
Lack of oxygen
Remove excess fire ice from around
the ignition well.
Thermocouple not in
Flame
Check that the tip of the thermocouple
is even with the top of the ignition well.
Remove any fire ice from the ignition
well.
Thermocouple connection
at the main control valve is
loose.
Tighten the thermocouple nut at the
back of the valve.
Burner won’t stay
lit after lighting
No fire ice on burner
Cover the burner with fire ice per the
instructions.