TROUBLESHOOTING GUIDE
PROBLEM
CAUSE
REMEDY
No Propane Gas at Burner
Check that gas tank valve is open. Turn
control knob to “ON” and push control knob
in. Make sure tank has propane gas.
No Spark at Electrode
Check that AA battery is installed with
negative (-) end first and has a charge.
Check that the wire is connected to the
ignition module. Check that the electrode is
not cracked or broken.
Burner won’t light
Lack of oxygen
Remove excess lava rocks or fire ice from
around the ignition well.
Thermocouple not in flame
Check that the tip of the thermocouple is
even with the top of the ignition well.
Remove any fire ice from the ignition well.
Thermocouple connection
at the main control valve is
loose
Tighten the thermocouple nut at the back of
the valve.
Burner won’t stay
lit after lighting
No Fire ice on Burner
Cover the burner with fire ice per the
instructions.