background image

Agilent Technologies

Vacuum Product Division

United States & Canada
Agilent Technologies 
Vacuum Products Division 
121 Hartwell Avenue 
Lexington, MA 02421 USA 
Tel: +1 781 861 7200
Toll-Free: +1 800 882 7426 
Fax: +1 871 860 5437 

Benelux 
Agilent Technologies 
Vacuum Products Division
 
Herculesweg 8 
4338 PL Middelburg
THE NETHERLANDS 
Tel: +31 118 671570
Fax: +31 118 671569

China 
Agilent Technologies 
Vacuum Products Division 
Room 1648
Central Tower South Wing 
Beijing Junefield Plaza 
No. 10 XuanWuMenWai Street 
Beijing 100052 P.R. CHINA 
Tel.: +86 (10) 6310 8550
Toll-Free: 800 820 6556 
Fax: +86 (10) 6310 0141 

France 
Agilent Technologies 
Vacuum Products Division 
7 avenue des Tropiques 
Z.A. de Courtaboeuf - B.P. 12 
91941 Les Ulis cedex FRANCE 
Tel.: +33 (0) 1 69 86 38 84 
Fax: +33 (0) 1 69 86 29 88 

Germany & Austria 
Agilent Technologies 
Vacuum Products Division
 
Alsfelder Strasse 6 
Postfach 11 14 35
64289 Darmstadt GERMANY 
Tel.: +49 (0) 6151 703 353
Fax: +49 (0) 6151 703 302 

India 
Agilent Technologies
Vacuum Product Division 
205-A, “A” wing of Galleria,
2nd floor, Hiranandani Gardens,
Powai, Mumbai-400 076, India
Tel.: +91 22-2570 8595 / 8597
Fax: +91 22- 2570 8599 

Italy 
Agilent Technologies 
Vacuum Products Division 
via F.lli Varian 54 
10040 Leini, (Torino) ITALY 
Tel.: +39 011 997 9111
Toll-Free: 00 800 234 234 00
Fax: +39 011 997 9350 

Japan 
Agilent Technologies 
Vacuum Products Division 
Sumitomo Shibaura Building 4-16-36
8th Floor
4-16-36 Shibaura Minato-ku 
Tokyo 108 JAPAN 
Tel.: +81 3 5232 1253
Toll-Free: 0120 655 040
Fax: +81 3 5232 1710 

Korea 
Agilent Technologies 
Vacuum Products Division 
Shinsa 2nd Bldg. 2F 966-5 
Daechi-dong 
Kangnam-gu, Seoul 
KOREA 135-280 
Tel.: +82 2 3452 2452
Toll-Free: 080 222 2452
Fax: +82 2 3452 2451 

Mexico 
Agilent Technologies 
Vacuum Products Division 
Concepcion Beistegui No 109 
Col Del Valle C.P. 03100 
MEXICO, D.F. 
Tel.: +52 5 523 9465
Fax: +52 5 523 9472 

Southeast Asia 
Agilent Technologies 
Vacuum Products Division 
South East Asia (SEA) - Alex Ho
H/P: +601 2213 1253 
Fax: +603 6733 8121 

Singapore 
Agilent Technologies
Vacuum Products Division
 
Singapore
Unit 10-04 Helios
Biopolis @ one-north
11 Biopolis Way, 138667
Singapore
H/P.: +65 92364988
Fax: +65 64789603

Taiwan 
Agilent Technologies 
Vacuum Products Division 
14F-6, No. 77, Hsin Tai Wu Road,
Sec. 1
Hsi chih, Taipei Hsien, Taiwan,
R.O.C.
Tel.: +886 2 2698 9555
Toll Free: 0800 051 342
Fax: +886 2 2698 9678

UK & Ireland 
Agilent Technologies 
Vacuum Products Division 
6 Mead Road 
Oxford Industrial Park 
Tel.: +44 (0) 1865 291570
Fax: +44 (0) 1865 291571 

Summary of Contents for TriScroll 610

Page 1: ...D R A F T 4 1 4 1 1 INSTALLATION AND OPERATION MANUAL Vacuum Products Division TriScrollTM 610 Dry Scroll Vacuum Pump Manual No 699904295 Revision F February 2005...

Page 2: ...gilent Inc TriScroll 610 Dry Scroll Vacuum Pump TriScroll is a trademark of Agilent Loctite and PST are registered trademarks of Loctite Corporation Krytox Teflon and Viton are registered trademarks o...

Page 3: ...ntents Contacting Agilent vi Specifications 1 Unpacking and Inspection 4 Installation 5 Safety 5 Electrical Connections 6 Operation 11 Start Up Procedure 11 Shutdown Procedure 11 Troubleshooting 12 Tr...

Page 4: ...TriScroll 610 Dry Scroll Vacuum Pump This page intentionally left blank D R A F T 4 1 4 1 1...

Page 5: ...ue se refiere esta declaraci n es conforme a la s norma s u otro s documento s normativo s waamaar deze verklaring verwijst aan de volende norm en of richtlijn en beantwoodt a cui se rifersce questa d...

Page 6: ...Agilent In the United States you can contact Agilent Customer Service at 1 800 882 7426 See the back cover of this manual for a listing of our sales and service offices Visit our web site at http www...

Page 7: ...nterface dimensions See Figure 2 on page 3 Peak pumping speed 50 Hz 420 I m 25 2 m3 hr 14 8 cfm 60 Hz 500 I m 30 m3 hr 17 6 cfm Ultimate pressure Torr 7 0 x 10 3 Torr 9 3 x 10 3 mbar Maximum inlet pre...

Page 8: ...1 00 HP 0 75 kW 3 phase 50 Hz 200 230 380 415 VAC 3 Phase 60 Hz 200 230 460 VAC Motor full load currents See Table 2 Motor thermal protection Type N automatic Operating speed 1725 RPM 60 Hz 1425 RPM...

Page 9: ...3 TriScroll 610 Dry Scroll Vacuum Pump Figure 2 TriScroll 610 Vacuum Pump Interface Drawing...

Page 10: ...removing the foam packing and this manual slit open the inner box Lift the pump with plywood base out of the inner box Remove the four bolts securing the pump frame to the plywood base Locate the NW2...

Page 11: ...se electric shock short circuits and severe bodily injury WARNING Before inspecting or servicing the pump be sure the electrical supply is disconnected Consult a qualified electrician when ever changi...

Page 12: ...e relevant electrical component manufacturer s instructions Table 2 lists the full load motor currents in Amps at various voltages Table 2 TriScroll 610 Full Load Motor Currents VAC 100 115 200 230 1...

Page 13: ...al cover in the groove provided The groove is sized for a 14 gauge cable A 1 2 14 NPSM hole is also provided next to the motor cover The clamp fitting is not provided 5 Wire L 1 and L2 per Figure 4 us...

Page 14: ...rotation With the intake uncovered a large gas flow should come out the pump exhaust If there is no flow out the exhaust reverse any two of the leads L 1 L2 or L3 Repeat the test to verify correct rot...

Page 15: ...Installation Data TriScroll Vacuum Pump VPI Valve Part NW25 VPI Valve Part NW40 Solenoid Operating Volt age Range Wiring Diagram 100 120 V 50 60 Hz 1 Phase VPI251205060 VPI401205060 90 132 V 50 60 Hz...

Page 16: ...clamp and inlet O ring 3 Remove three 3 M5 screws item 1 on Figure 1 on page 1 that secure the cowling to the scroll module Remove the cowling 4 Tilt the pump back so that the rear end of the motor to...

Page 17: ...g purge port item 6 on Figure 1 on page 1 is provided to protect the main crankshaft bearings in applications where large amounts of water are being pumped In the standard configuration the port is se...

Page 18: ...ectrical cover Inspect and repair Wiring loose or cut Repair or replace Excessive voltage drop Check size and length of cable Defective motor Inspect Contact Agilent Poor ultimate pressure System leak...

Page 19: ...0 series pumps are listed in Table 5 Maintenance and Tooling Kits Material and tooling required to perform maintenance on TriScroll pumps is provided in kit form A description of each kit and ordering...

Page 20: ...Scroll Model Table 7 Factory Service Options Model Factory Service Options EXPPTS06001 Advance Exchange TriScroll 600 Single Phase Pump EXPPTS06003 Advance Exchange TriScroll 600 Three Phase Pump EXPP...

Page 21: ...the core product e g inlet screens vent valves x Prior to shipment drain any oils or other liquids purge or flush all gasses and wipe off any excess residue x If ordering an Advance Exchange product...

Page 22: ...ed or been exposed to any toxic or hazardous materials OR HAS pumped or been exposed to the following toxic or hazardous materials If this box is checked the following information must also be filled...

Page 23: ...Other Vacuum leak Other Section 6 ADDITIONAL TERMS Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent Technologies Vacuum Product Division Prod...

Page 24: ...TriScroll 610 Dry Scroll Vacuum Pump This page intentionally left blank...

Page 25: ......

Page 26: ...y Agilent Technologies Vacuum Products Division via F lli Varian 54 10040 Leini Torino ITALY Tel 39 011 997 9111 Toll Free 00 800 234 234 00 Fax 39 011 997 9350 Japan Agilent Technologies Vacuum Produ...

Reviews: