Installation Procedure
Uninstalling Option 1DS
1. Locate the RF section on the right side of the instrument.
locations and the preamplifier mounting orientation.
Figure 3
Preamplifier Location
2. Locate and remove cable W55 (SBTX to FIFA rear connector), E4446-20045. This
cable will be replaced later. It is removed to allow the preamplifier assembly to be
removed.
3. Locate and remove cable W56 (FIFA front connector to Band Pass filter),
E4446-20046. This cable will be replaced later. It is removed to allow the preamplifier
assembly to be removed.
4. Locate and remove cable W39 (low band assembly J4 to band pass filter),
E4446-20058, using the 5/16-inch wrench. This cable will be replaced later. It is
removed to allow the preamplifier assembly to be removed.
5. Locate and remove cable W50 (preamplifier J2 and low band assembly J1 RF IN).
Discard this cable, since it will be replaced by another cable.