5-28
N9360A Multi UE Tester W-CDMA Programming Manual
5
Programming Command Reference
Command Reference for Configuration: Test Condition Screen
The Condition commands are used to set the controls and
parameters associated with the test condition including the
pass or fail test limits for Automatic Test and Manual Test. The
query commands return the settings of those controls and
parameters.
Radio System
CONFigure:CONDition:RFORmat W-CDMA
CONFigure:CONDition:RFORmat?
This command selects a Radio System to be tested. Only
W-CDMA
is available.
Band
CONFigure:CONDition:BAND <int>
CONFigure:CONDition:BAND?
This command sets the Band number. The parameter is
1
or
6
.
At preset, this is set to
1
.
This query command returns the set Band number with integer.
Averaging
CONFigure:CONDition:AVERage OFF|<int>
CONFigure:CONDition:AVERage?
This command sets whether or not to activate the averaging.
The parameter is
OFF
or
<int>
for the number of averaging
times. The allowable range of
<int>
is from
2
to
99
. At preset,
this is set to
OFF
.
This query command returns the set averaging.
BS Level
CONFigure:CONDition:AMPLitude <real>
CONFigure:CONDition:AMPLitude?
Summary of Contents for N9360A
Page 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...
Page 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...