Agilent products are designed for use with

electrical signals that are rated Meas-

urement Category I and Measurement Cat-

egory II, as described in the International

Electrotechnical Commission (IEC) Standard

IEC 60664. Most measurement, control, and

data I/O signals are Measurement Category

I and must not be directly connected to

mains voltage or to voltage sources with

high transient over-voltages. Measurement

Category II connections require protection

for high transient over-voltages often asso-

ciated with local AC mains connections.

Assume all measurement, control, and data

I/O connections are for connection to Cat-

egory I sources unless otherwise marked or

described in the user documentation.

Exercise extreme caution when a shock haz-

ard is present. Lethal voltage may be present

on cable connector jacks or test fixtures. The

American National Standards Institute

(ANSI) states that a shock hazard exists

when voltage levels greater than 30V RMS,

42.4V peak, or 60VDC are present. A good

safety practice is to expect that hazardous

voltage is present in any unknown circuit

before measuring.

Operators of this product must be protected

from electric shock at all times. The respon-

sible body must ensure that operators are

prevented access and/or insulated from

every connection point. In some cases, con-

nections must be exposed to potential

human contact. Product operators in these

circumstances must be trained to protect

themselves from the risk of electric shock. If

the circuit is capable of operating at or

above 1000V, no conductive part of the cir-

cuit may be exposed.

Do not connect switching cards directly to

unlimited power circuits. They are intended

to be used with impedance-limited sources.

NEVER connect switching cards directly to

AC mains. When connecting sources to

switching cards, install protective devices to

limit fault current and voltage to the card.

Before operating an instrument, ensure that

the line cord is connected to a properly-

grounded power receptacle. Inspect the con-

necting cables, test leads, and jumpers for

possible wear, cracks, or breaks before each

use.

When installing equipment where access to

the main power cord is restricted, such as

rack mounting, a separate main input power

disconnect device must be provided in close

proximity to the equipment and within easy

reach of the operator.

For maximum safety, do not touch the prod-

uct, test cables, or any other instruments

while power is applied to the circuit under

test. ALWAYS remove power from the entire

test system and discharge any capacitors

before: connecting or disconnecting cables or

jumpers, installing or removing switching

cards, or making internal changes, such as

installing or removing jumpers.

Do not touch any object that could provide a

current path to the common side of the cir-

cuit under test or power line (earth) ground.

Always make measurements with dry hands

while standing on a dry, insulated surface

capable of withstanding the voltage being

measured.

The instrument and accessories must be

used in accordance with its specifications

and operating instructions, or the safety of

the equipment may be impaired.

Do not exceed the maximum signal levels of

the instruments and accessories, as defined

in the specifications and operating infor-

mation, and as shown on the instrument or

test fixture panels, or switching card.

When fuses are used in a product, replace

with the same type and rating for continued

protection against fire hazard.

Chassis connections must only be used as

shield connections for measuring circuits,

NOT as safety earth ground connections.

If you are using a test fixture, keep the lid

closed while power is applied to the device

under test. Safe operation requires the use

of a lid interlock.

A

CAUTION

notice denotes a hazard. It

calls attention to an operating procedure,

practice, or the like that, if not correctly

performed or adhered to, could result in

damage to the product or loss of important

data. Do not proceed beyond a

CAUTION

notice until the indicated conditions are

fully understood and met.

A WARNING notice denotes a hazard. It

calls attention to an operating pro-

cedure, practice, or the like that, if not

correctly performed or adhered to, could

result in personal injury or death. Do not

proceed beyond a WARNING notice until

the indicated conditions are fully under-

stood and met.

Instrumentation and accessories shall not be

connected to humans.

Before performing any maintenance, dis-

connect the line cord and all test cables.

To maintain protection from electric shock

and fire, replacement components in mains

circuits – including the power transformer,

test leads, and input jacks – must be pur-

chased from Agilent. Standard fuses with

applicable national safety approvals may be

used if the rating and type are the same.

Other components that are not safety-

related may be purchased from other sup-

pliers as long as they are equivalent to the

original component (note that selected parts

should be purchased only through Agilent to

maintain accuracy and functionality of the

product). If you are unsure about the appli-

cability of a replacement component, call an

Agilent office for information.

No operator serviceable parts inside.

Refer servicing to qualified personnel. To

prevent electrical shock do not remove

covers. For continued protection against

fire hazard, replace fuse with same type

and rating.

Summary of Contents for M9302A

Page 1: ...cillator 3 GHz to 10 GHz Startup Guide NOTICE This document contains references to Agilent Technologies Agilent s former Test and Measurement business has become Keysight Technologies For more informa...

Page 2: ...software is for use in the performance of a U S Government prime contract or sub contract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995...

Page 3: ...ing cables or jumpers installing or removing switching cards or making internal changes such as installing or removing jumpers Do not touch any object that could provide a current path to the common s...

Page 4: ...rdous or toxic substance ele ments are expected to leak or deteriorate during normal use Forty years is the expected useful life of the product This symbol indicates the instrument is sen sitive to el...

Page 5: ...n Procedure 12 Step 4 Install the Module 13 Recommended Practices for Temperature Control 13 Module Installation Procedure 13 Agilent M9302A PXI Local Oscillator Front Panel Features 15 Front Panel Co...

Page 6: ......

Page 7: ...Documentation Map Documentation Map Agilent M9302A PXI Local Oscillator Startup Guide 7...

Page 8: ...e CD and at www agilent com find M9302A go to Document Library Manuals l M9302A Soft Front Panel help system l M9302A device driver API help systems IVI C IVI COM and LabVIEW G l M9302A specifications...

Page 9: ...cking a module inspect it for any shipping damage Report any damage to the shipping agent imme diately as such damage is not covered by the warranty see warranty information at beginning of this docum...

Page 10: ...es contained on the CDs are available for download at www agilent com find M9302A Step 3 Install the Software System Requirements Topic Windows 7 and Vista Requirements Windows XP Requirements Operati...

Page 11: ...interface cable you must power up the chassis BEFORE you power up the PC When you power down your chassis Shut Down the PC BEFORE you power down the chassis If you are using an embedded controller co...

Page 12: ...r Signal Analyzer Software and Product Information CD M9392 10002 launch the installer b Follow the installer prompts Choose a Complete installation to install all software and doc umentation or a Cus...

Page 13: ...ity image a circle containing the slot number The module can also be installed in any hybrid PXI slot marked with a peripheral slot com patibility image the letter H and a solid circle containing the...

Page 14: ...the screws are not tightened properly 8 Verify that the PXI chassis fans are operable and free of dust and other contaminants that may restrict airflow 9 Install filler panels and slot blockers after...

Page 15: ...T This SMA female connector is used to deliver the local oscillator sig nal 3 GHz to 10 GHz out of the front panel Front Panel LEDs LED Description STATUS This LED indicates the overall health of the...

Page 16: ...rigid SMA SMA M9361A A4 M9361 20002 M9360A LO 2 OUT M9361A LO IN Cable semi rigid SMA SMA M9351A A5 M9351 20002 M9360A LO 1 OUT M9351A LO IN Cable semi rigid SMA SMA M9351A B1 8120 5016 M9351A REF IN...

Page 17: ...ent IO Libraries Suite Agilent Connection Expert It will display the modules that are installed Review the configuration data and then launch the SFP This will provide control of the module for self t...

Page 18: ...are the signal paths to the 10 MHz REF OUT and the two 100 MHz REF OUT connectors The fol lowing process demonstrates that all associated connectors cables and circuitry are operational Required Hardw...

Page 19: ...f these downconverters 1 Run the M9302A soft front panel SFP 2 Conduct a Self Test Utility Self Test Run Self Test a If self test passes go to next step b If self test fails the module needs repair Se...

Page 20: ...the following checks 1 Verify that all relevant hardware is turned on 2 Verify that the M9302A paths are correctly set from the SFP and that the signal generator is set to the proper power frequency a...

Page 21: ...C Program Files IVI Foundation IVI Drivers AgM9302 Example programs are provided to dem onstrate most driver functionality for example C Program Files IVI Foundation IVI Drivers AgM9302 Exa mples The...

Page 22: ...facturers Group PCIe and PCI EXPRESS are registered trademarks and or service marks of PC SIG Microsoft Windows VisualStudio VisualC VisualC and VisualBasic are either registered trademark or trademar...

Reviews: