background image

Installation Note E4400-90214

 5

Upgrade Kit E4400-60166 Contents

Item

Quantity

Description

Part 

Number

Std (No 

Opt’s

a

)

a Implies no other digital hardware installed.

UN7

1

1

0

This installation note

E4400-90214

2

1

1

Dual arbitrary waveform generator board

E4400-60187

3

1

0

Rear-panel interface board

E4400-60145

4

1

0

Rear panel (Option UND)

E4400-00031

5

1

0

W3, DATA to motherboard or
DATA to Data Generator (A8J2) (Option UN3/4 or UN8/9)

8120-5063

6

1

0

W4, DATA CLOCK to motherboard or
DATA CLOCK to Data Generator (A8J1) (Option UN3/4 or UN8/9)

8120-5063

7

1

0

W5, SYMBOL SYNC to motherboard or 
SYMBOL SYNC to Data Generator (A8J3) (Option UN3/4 or UN8/9)

8120-5063

8

1

0

W15, dual arbitrary waveform generator (A5J3) to BASEBAND 
GEN REF IN (13 MHz)

8120-5055

9

1

0

W16, dual arbitrary waveform generator (A5J2) to Q OUT

8120-5055

10

1

0

W17, dual arbitrary waveform generator (A5J1) to I OUT

8120-5055

11

1

0

W18, rear-panel interface board (A17) to dual arbitrary waveform 
generator (A5P1) ribbon cable

8120-8458

12

1

1

W24, for future use with Options UND and UN3/4 or
Options UND and UN8/9

E4400-20131

13

11

0

Washer, lock 0.4721D

2190-0102

14

3

0

Washer, lock 0.4091D

3050-1919

15

14

0

Nut, hex 15/32-32

2950-0035

16

3

0

Plug, hole 0.500D

6960-0002

17

1

0

Label, Option UND serial number

7120-1232

18

1

0

Label, front-panel overlay-connectors (Option UND)

E4400-80006

19

1

0

Safety solvent cleaner

8500-6269

20 

1

0

Firmware Upgrade Kit

E4400-60230

21

1

0

W25, INT Q coax cable A14P103 to Daughter board A15J8

8120-8748

22

1

0

W26, INT I coax cable A14P102 to Daughter board A15J9

8120-8748

23

b

b For ESG-DP Models E4434B, E4435B, E4436B and E4437B.

1

0

W25, INT Q coax cable A14P103 to Daughter board A15J8

8120-8781

24

b

1

0

W26, INT I coax cable A14P102 to Daughter board A15J9

8120-8781

Summary of Contents for E4400-60166

Page 1: ...ober 2004 Supersedes July 2000 Installation Note Agilent Technologies ESG D and ESG DP Series Signal Generators Option UND Upgrade Kit Part Numbers E4400 60166 and E4400 60181 Models E4430B E4431B E44...

Page 2: ...his material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Agilent Technologies shall not be liable for errors contained herein or for inc...

Page 3: ...tion in its entirety and in the order presented Product Affected ESG D and ESG DP Series Signal Generators Models Affected E4430B E4431B E4432B E4433B E4434B E4435B E4436B and E4437B Serial Numbers Al...

Page 4: ...ewdriver Break away torque wrench 9 in lbs Ratchet 21 in lbs Socket 9 16 Socket 3 8 Hand torque driver 9 in lbs socket 9 32 Hand torque driver 6 in lbs socket 3 16 Scissors WARNING Before you disassem...

Page 5: ...m generator A5J2 to Q OUT 8120 5055 10 1 0 W17 dual arbitrary waveform generator A5J1 to I OUT 8120 5055 11 1 0 W18 rear panel interface board A17 to dual arbitrary waveform generator A5P1 ribbon cabl...

Page 6: ...tronic assemblies should be performed at a static safe workstation Upgrade Kit E4400 60181 Contents Item Quantity Description Part Number Std No Opt s UN7 UN3 4 or UN8 9 1 1 0 0 This installation note...

Page 7: ...R 514 Reference Oven Cold will occur whenever the signal generator is first connected to the AC line power This error cannot be cleared from the error queue until the internal reference has warmed up...

Page 8: ...sening the two screws item 2 on each handle 4 Remove the four rear feet item 4 from the signal generator by removing the four screws item 5 that secure them 5 Slide the signal generator top cover item...

Page 9: ...1 Refer to Figure 3 on page 10 Remove the 15 screws item 2 that secure the bottom chassis cover item 3 and lift the chassis cover off 2 Refer to Figure 4 on page 11 Disconnect A16W1 from the power su...

Page 10: ...shers that secure the AUXILIARY INTERFACE item 3 and GPIB item 4 connectors to the rear panel 5 Remove the 10 screws item 5 that secure the rear panel to the signal generator chassis 6 Remove the two...

Page 11: ...Installation Note E4400 90214 11 Figure 4 Removing the Rear Panel and Rear Panel Parts...

Page 12: ...ear panel using the washer and hex nut Torque to 21 in lbs 3 Attach the COHERENT CARRIER cap and chain screw to the rear panel Torque to 9 in lbs 4 Insert W15 into the rear panel hole for the BASEBAND...

Page 13: ...Reinstall the hex screws and washers for the GPIB connector Torque to 9 in lbs 4 Reinstall the nuts and washers securing the BNC connectors at the base of the rear panel Torque to 21 in lbs 5 Reconnec...

Page 14: ...from the center outward this prevents air bubbles from forming 5 Reinstall W1 in the I input connector hole now located at the top Attach it to the BNC with a hex nut and spring washer Torque to 21 in...

Page 15: ...Installation Note E4400 90214 15 Figure 6 Front Panel...

Page 16: ...the A5J2 connector on the A5 dual arbitrary waveform generator board to Q OUT on the rear panel 6 Connect W15 from the A5J3 connector on the A5 dual arbitrary waveform generator board to the BASEBAND...

Page 17: ...from the A17 rear panel interface board to the A5 dual arbitrary waveform generator board if Options UN3 4 are installed or the A7 real time I Q baseband generator if Option UN8 9 is installed 4 Disco...

Page 18: ...18 Installation Note E4400 90214 Figure 8 Cable Locations Options UN8 9 Installed Figure 9 Cables W25 and W26...

Page 19: ...ear Panel to A7P405 DATA W3 5 Front Panel to A14P5 SYMBOL SYNC W5 6 Front Panel to A14P7 DATA CLOCK W4 7 Front Panel to A14P6 REAR PANEL INTERFACE CABLE W18 Rear Panel Interface A17 to A8P2 INT Q W25...

Page 20: ...generator s power switch off and disconnect the line cord 2 Refer to Figure 2 on page 9 Reinstall the signal generator top chassis cover with the 11 top chassis cover screws Torque the screws to 9 in...

Reviews: