182
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\prog_prog_guide_step5.fm
Step 5: Set the Mobile Station’s Operating Conditions
Step 5: Set the Mobile Station’s Operating Conditions
Overview
The mobile station’s operating conditions are set using the CALL processing subsystem commands shown in
the following table.
Table Footnotes
1 The TCH band setting becomes the selected band.
Example 1. Programming Example:
!**********************************************************************
! Step 5: Set Mobile Station Operating Conditions
!**********************************************************************
!
OUTPUT Test_set;”CALL:MS:DTX OFF”
OUTPUT Test_set;”CALL:MS:TXL 14
Settable Mobile Station Operating Conditions
Parameter
Command Syntax
Table Footnotes
Timing Advance
CALL:MS:TADVance <numeric value>
Transmit Level
CALL:MS:TXLevel[:SELected] <numeric value>
OR
CALL:MS:TXLevel:<PGSM|EGSM|DCS|PCS> <numeric value>
Discontinuous
Transmission
CALL:MS:DTX[:STATe] <ON|1|OFF|0>