Agilent Technologies 85097B Reference Manual Download Page 20

3-2

Chapter 3

 

Safety and Regulatory Information

Safety Information

Safety Information

Review this product and related documentation to familiarize yourself with safety 
markings and instructions before you operate the instrument. This product has been 
designed and tested in accordance with international standards.

WARNING

The WARNING notice denotes a hazard. It calls attention to a 
procedure, practice, or the like, that, if not correctly performed or 
adhered to, could result in personal injury. Do not proceed beyond a 
WARNING notice until the indicated conditions are fully understood 
and met.

CAUTION

The CAUTION notice denotes a hazard. It calls attention to an operating 
procedure, practice, or the like, which, if not correctly performed or adhered 
to, could result in damage to the product or loss of important data. Do not 
proceed beyond a CAUTION notice until the indicated conditions are fully 
understood and met.

Before Applying Power

Verify that the product is configured to match the available main power source as 
described in 

Table 1-4 on page 1-9

. If this product is to be powered by autotransformer, 

make sure the common terminal is connected to the neutral (grounded) side of the ac 
power supply.

WARNING

Install the instrument so that the detachable power cord is readily 
identifiable and is easily reached by the operator. The detachable 
power cord is the instrument disconnecting device. It disconnects 
the mains circuit from the mains supply before other parts of the 
instrument. 

WARNING

If this product is not used as specified, the protection provided by 
the equipment could be impaired. This product must be used in a 
normal condition (in which all means for protection are intact) only.

Summary of Contents for 85097B

Page 1: ...echnologies 85097B VNA Interface Kit for Electronic Calibration Manufacturing Part Number 85091 90010 Printed in USA Print Date March 2003 Supersedes October 2001 Copyright 2001 2003 Agilent Technologies Inc All rights reserved ...

Page 2: ...ALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING USE OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN SHOULD AGILENT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL Assistance P...

Page 3: ... Procedure 1 6 VNA Interface Kit Characteristics 1 8 Environmental Requirements 1 8 Electrical and Mechanical Characteristics 1 9 Electrostatic Discharge 1 10 2 Troubleshooting General Information 2 2 Returning a VNA Interface Kit to Agilent 2 2 Contacting Agilent 2 4 3 Safety and Regulatory Information Safety Information 3 2 Before Applying Power 3 2 Instrument Markings 3 3 Safety Earth Ground 3 ...

Page 4: ...Contents ii Contents ...

Page 5: ...1 1 1 General Information ...

Page 6: ... about ECal modules refer to the Electronic Calibration Module Reference Guide included with the VNA interface kit Option 100 Adds an adapter cable that allows the interface kit to connect to N469x microwave ECal modules The Option 100 adapter cable can also be ordered separately Compatible Network Analyzers Refer to Table 1 1 for network analyzers and ECal modules compatible with the 85097B VNA i...

Page 7: ...t Figure 1 1 85097B Kit Contents Table 1 2 Contents of the VNA Interface Kit Description Quantity Part Number Interface Unit 1 85097 60002 Shielded Cable DB25 to DB25 3 8120 8710 Adapter Cable DB25 to AMP Champ Option 100 1 8120 1047 Power Supply 1 0950 3331 VNA Interface Kit Reference Guide this manual 1 85091 90010 Electronic Calibration Module Reference Guide 1 N4693 90001 ...

Page 8: ...er must be installed in the module to make it compatible with the interface unit Contact Agilent for information about returning your module for this modification Contact information can be found in Table 2 1 on page 2 4 Shielded Cables DB25 to DB25 The shielded cables shown in Figure 1 1 are male to male RS 232 cables Three shielded cables are included in the kit The cables connect between the VN...

Page 9: ...om mains before cleaning Use a dry cloth or one slightly dampened with water to clean the external case parts Do not attempt to clean internally CAUTION Always use the three prong ac power cord supplied with this product Failure to insure adequate earth grounding by not using this cord may cause product damage WARNING The detachable power cord is the instrument disconnecting device It disconnects ...

Page 10: ...interface cable to an unspecified connector on the VNA will cause damage Connect RF Module to Interface Unit DB25 to DB25 Cable 1 Connect one end of the DB25 to DB25 cable to the parallel port on the ECal module 2 Connect the other end of the DB25 to DB25 cable to the connector on the interface unit labeled DB25 Interface to ECal Module A or DB25 Interface to ECal Module B Connect Microwave Module...

Page 11: ...ules can be connected or disconnected when the analyzer is turned on or off but must remain connected while data transfer is in progress After completing a calibration the ECal module or modules can remain connected to the interface unit With the appropriate interface cable RF or microwave ECal modules can be connected to position A or B of the interface unit ...

Page 12: ... operating temperature of the system by 4 C for every 100 watts dissipated in the cabinet If the total power dissipated in the cabinet is greater than 800 watts then forced convection must be used CAUTION Install the instrument according to the enclosure protection provided This instrument does not protect against the ingress of water This instrument protects against finger access to hazardous par...

Page 13: ... is within the specified range Table 1 4 Power Supply Electrical and Mechanical Characteristics Characteristics Limits Power Requirements Line Voltage Line Frequency 100 to 240 Vac 50 to 60 Hz Power Output 24 Vdc 1 A Power Dissipation 192 VA Maximum Safety IEC 950 Weights Net Weight Shipping Weight 0 7 kg 1 5 lbs 3 kg 6 5 lbs Dimensions Height Width Length 41 mm 1 6 in 158 mm 6 2 in 97 mm 3 8 in ...

Page 14: ...heel strap when working in an area with a conductive floor If you are uncertain about the conductivity of your floor wear a heel strap always ground yourself before you clean inspect or make a connection to a static sensitive device or test port You can for example grasp the grounded outer shell of the test port or cable connector briefly always ground the center conductor of a test cable before m...

Page 15: ...2 1 2 Troubleshooting ...

Page 16: ...g a VNA Interface Kit to Agilent If any device in the interface kit requires service contact Agilent for information on where to send it See Table 2 1 on page 2 4 When transporting the kit use original or comparable packaging Please include the following information with your returned interface kit your company name and address a technical contact person within your company and the person s comple...

Page 17: ...Chapter 2 2 3 Troubleshooting General Information Figure 2 1 Troubleshooting Flowchart ...

Page 18: ...el 0 800 738 378 fax 64 4 495 8950 Japan tel 81 426 56 7832 fax 81 426 56 7840 Australia tel 1 800 629 485 fax 61 3 9210 5947 Singapore tel 1 800 375 8100 fax 65 836 0252 Malaysia tel 1 800 828 848 fax 1 800 801 664 Philippines tel 632 8426802 tel PLDT subscriber only 1 800 16510170 fax 632 8426809 fax PLDT subscriber only 1 800 16510288 Thailand tel outside Bangkok 088 226 008 tel within Bangkok ...

Page 19: ...3 1 3 Safety and Regulatory Information ...

Page 20: ... to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met Before Applying Power Verify that the product is configured to match the available main power source as described in Table 1 4 on page 1 9 If this product is to be powered by autotransformer make sure the common terminal is connected...

Page 21: ... ensure safe operation and to maintain the product in a safe condition When you see this symbol on your instrument you should refer to the instrument s instruction manual for important information This symbol indicates hazardous voltages The laser radiation symbol is marked on products that have a laser output This symbol indicates that the instrument requires alternating current ac input The CE m...

Page 22: ...rmity and has been supplied in a safe condition The documentation contains information and warnings that must be followed by the user to ensure sate operation and to maintain the product in a safe conditions Compliance with Canadian EMC Requirements This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB du Canada Compliance With EEC Directives See the declarat...

Page 23: ...Chapter 3 3 5 Safety and Regulatory Information Regulatory Information VNA Interface Kit Declaration of Conformity ...

Page 24: ...3 6 Chapter3 Safety and Regulatory Information Regulatory Information ...

Page 25: ...atic discharge 1 10 environmental requirements 1 8 ESD 1 10 precautions 1 10 F firmware revisions compatible 1 2 I instrument marking descriptions 3 3 interface kit content descriptions 1 4 option 100 1 2 replaceable parts 1 3 interface kit contents 1 3 interface unit description 1 4 M maintenance 1 10 mechanical characteristics 1 9 O online assistance 2 4 option 100 1 2 P PNA ECal interface 1 2 p...

Reviews: