Agilent Technologies 16092A Operation And Service Manual Download Page 2

2

 

Notices

The information contained in this document is subject to change without notice.

This document contains proprietary information that is protected by copyright.All rights 
are reserved. No part of this document may be photocopied, reproduced, or translated to 
another language without the prior written consent of the Agilent Technologies.

Agilent Technologies Japan, Ltd.

Kobe Instrument Division

1-3-2, Murotani, Nishi-Ku, Kobe-shi, Hyogo, 651-2241 Japan

© Copyright  Agilent Technologies Japan, Ltd. 1986, 1998, 2000

Manual Printing History

The manual’s printing date and part number indicate its current edition. The printing date 
changes when a new edition is printed. (Minor corrections and updates that are 
incorporated at reprint do not cause the date to change.) The manual part number changes 
when extensive technical changes are incorporated.

December 1986  

First Edition (part number: 16092-90000)

November 1998  

Second Edition (part number: 16092-90010)

February 2000  

Third Edition (part number: 16092-90010)

Safety Summary

The following general safety precautions must be observed during all phases of operation, 
service, and repair of this instrument. Failure to comply with these precautions or with 
specific WARNINGS elsewhere in this manual may impair the protection provided by the 
equipment. In addition it violates safety standards of design, manufacture, and intended use 
of the instrument.

The Agilent Technologies assumes no liability for the customer’s failure to comply with 
these requirements.

NOTE

16092A comply with INSTALLATION CATEGORY II and POLLUTION DEGREE 2 in 
IEC61010-1. 16092A are INDOOR USE product.

Ground The Instrument

To avoid electric shock hazard, the instrument chassis and cabinet must be connected 
to a safety earth ground by the supplied power cable with earth blade.

DO NOT Operate In An Explosive Atmosphere

Summary of Contents for 16092A

Page 1: ...t 16092A Test Fixture Operation and Service Manual Third Edition Agilent Part No 16092 90010 February 2000 Printed in Japan Advanced Test Equipment Rentals www atecorp com 800 404 ATEC 2832 Establishe...

Page 2: ...l changes are incorporated December 1986 First Edition part number 16092 90000 November 1998 Second Edition part number 16092 90010 February 2000 Third Edition part number 16092 90010 Safety Summary T...

Page 3: ...ized modifications to the instrument Return the instrument to a Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained Dangerous Procedure W...

Page 4: ...d corresponding to the individual warranty periods of its component products Instruments are warranted for a period of one year Fixtures and adapters are warranted for a period of 90 days During the w...

Page 5: ...l damages whether based on contract tort or any other legal theory Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products Fo...

Page 6: ...6...

Page 7: ...Contents 7 1 Operation Description 11 2 Service Maintenance 14...

Page 8: ...8 Contents...

Page 9: ...ure 1 1 was specially designed for use with the 4191A RF Impedance Analyzer How to use the 16092A performance characteristic data and operating instructions are given in the 4191A s operation and serv...

Page 10: ...10 Chapter1 Operation Figure 1 1 16092A Test Fixture...

Page 11: ...m shorting configuration between the High terminal and ground of the test fixture When the test fixture is short circuited the residual resistance and inductance of the fixture terminal can be measure...

Page 12: ...12 Chapter1 Operation Description...

Page 13: ...13 2 Service...

Page 14: ...d view Do not disassemble any further than shown in the figure To order the necessary replacement parts identify them by their Agilent Technologies part number If a defective part is located in an ass...

Page 15: ...Chapter 2 15 Service Maintenance Figure 2 1 Parts Identification...

Page 16: ...460 0350 1 SPRING 10 2190 0125 1 WASHER 11 0520 0174 1 SCREW 12 0520 0133 2 SCREW 13 2190 0103 2 WASHER 14 16092 40010 2 HOLDER 15 2190 0125 2 WASHER 16 16092 24012 2 SCREW 17 1460 0352 2 SPRING 18 16...

Page 17: ...the contact from the connector The replacement procedure is outlined below 1 Grip the Pin vise and fully open the vise chuck by pressing the button on the vise 2 Place the Pin vice over the center con...

Page 18: ...surfaces it is recommended that the operator perform periodic cleaning as necessary Use a lint free cloth and if a cleaning fluid is needed use isopropylalcohol CAUTION Do not use aromatic or chlorina...

Reviews: