Agilent Technologies 16047E Operation And Service Manual Download Page 4

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for 16047E

Page 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Page 2: ...0623 1 PLATE H 2 16047 00624 1 PLATE L 3 16047 24024 4 NUT 4 16047 00622 2 PLATE 5 16047 23021 2 SHAFT 6 16380 24001 4 TERMINAL 7 2950 0043 4 NUT 8 2190 0016 2 Washer 9 16047 09001 1 INSULATOR 10 16047 00625 1 SHIELD 11 16047 24022 1 SCREW 12 16047 00621 1 SHORT BAR 13 16047 04021 1 COVER 14 16047 60015 2 BNC LEVER ASSEMBLY 15 16047 60016 2 CONNECTOR BNC 16 16047 00626 1 CONTACT 17 16047 24023 2 S...

Page 3: ...する可能性がありますので 本器に衝撃を与えないように 取扱いには 破損する可能性がありますので 本器に衝撃を与えないように 取扱いには 破損する可能性がありますので 本器に衝撃を与えないように 取扱いには 注意してください 特に上面 注意してください 特に上面 注意してください 特に上面 注意してください 特に上面 試料を載せる面 側は 部品位置が精密に調 試料を載せる面 側は 部品位置が精密に調 試料を載せる面 側は 部品位置が精密に調 試料を載せる面 側は 部品位置が精密に調 整されており 細かな部品も使用されておりますので 絶対に衝撃を与えな 整されており 細かな部品も使用されておりますので 絶対に衝撃を与えな 整されており 細かな部品も使用されておりますので 絶対に衝撃を与えな 整されており 細かな部品も使用されておりますので 絶対に衝撃を与えな いで下さい 例えば 上面側を下にし...

Page 4: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 5: ...6047E Test Fixture Operation and Service Manual Third Edition Agilemt Part No 16047 90040 January 2001 Printed in Japan Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 6: ...ed at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated April 1999 First Edition part number 16047 90040 December 1999 Second Edition part number 16047 90040 January 2001 Third Edition part number 16047 90040 Safety Summary The following general safety precautions must be observed during all phases of operation service and repa...

Page 7: ...rts or perform unauthorized modifications to the instrument Return the instrument to a Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained Dangerous Procedure Warnings Warnings such as the example below precede potentially dangerous procedures throughout this manual Instructions contained in the warnings must be followed WARNING Danger...

Page 8: ... Agilent Technologies for use with an instrument will execute its programming instruction when property installed on that instrument Agilent Technologies does not warrant that the operation of the instrument or software or firmware will be uninterrupted or error free Limitation Of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer ...

Page 9: ...ion of push button switch Frame or chassis terminal A connection to the frame chassis of the equipment which normally include all exposed metal structure WARNING This warning sign denotes a hazard It calls attention to a procedure practice condition or the like which if not correctly performed or adhered to could result in injury or death to personnel CAUTION This Caution sign denotes a hazard It ...

Page 10: ...6 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 11: ... Compensation 20 Performing Open Compensation 20 Performing Short Compensation 20 Performing Load Compensation 21 DUT Measurement 22 Measuring 3 terminal device 23 4 Specifications and Supplemental Performance Characteristics Specifications 26 Supplemental Performance Characteristics 27 Additional Error 27 5 Service Maintenance 32 Replacable Parts 32 Artisan Technology Group Quality Instrumentatio...

Page 12: ...8 Contents Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 13: ...9 1 Installation Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 14: ...nts are incomplete if there is mechanical damage or defect notify the nearest Agilent Technologies office If the shipping container is damaged or the cushioning material shows signs of unusual stress notify the carrier as well as the Agilent Technologies office Keep the shipping materials for the carrier s inspection Table 1 1 Contents Description Part Number Qty 16047E Test Fixture 1 Shorting bar...

Page 15: ...ng test connectors by gradually turning the two BNC connectors rotation levers until each pair of connectors are securely connected Be sure to align the grooves on both sides Step 3 Turn clockwise the fixture s two fastening screws together so that the fixture is secured to the instrument Step 4 Finally secure the remaining two BNC connectors of the fixture by turning clockwise their rotation leve...

Page 16: ... fixture to the UNKNOWN connectors on the instrument by gradually coupling the four BNC connectors and fastening screws of the fixture with the connectors of the instrument until they come to complete contact Be sure to align the grooves on both sides Step 2 Secure the two BNC connectors of the fixture by turning clockwise their rotation levers Figure 1 3 Connecting the fixture to the instrument A...

Page 17: ...ectrodes get dirty their contact resistance increases resulting in inaccurate measurement Use soft cloth to clean the electrode to remove dust particles or any other dirt Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 18: ...14 Chapter1 Installation Guide Cleaning Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 19: ...15 2 Overview Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 20: ... the 4294A the fixture provides highly accurate measurement with wide frequency range up to 110 MHz Also it gains mechanical stability and a prolonged life when it is secured to the 4294A with its fastening screws Figure 2 1 Product Overview Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 21: ...nt s LCUR LPOT and the HIGH side electrode connected to an instrument s HCUR HPOT 2 Electrode securing screws Secures the electrodes with DUT leads caught 3 Fixture fastening screws Secures the fixture to an instrument 4 Shorting bar Detached and used as a shorting bar when performing short correction Also used as a guard terminal securing plate when measuring a 3 terminal device Artisan Technolog...

Page 22: ...18 Chapter2 Overview Functions Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 23: ... Operation This chapter describes the proper methods for fixture compensation with the 16047E and DUT measurement Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 24: ...and LOW sides with no DUT leads caught in the electrodes NOTE Do not fasten the screws too tightly to prevent the electrodes from damaged 2 Follow the instruction manual that came with your instrument to perform a measurement to obtain open compensation data Performing Short Compensation The short compensation procedure is as follows 1 Remove the shorting bar secured on the guard terminal 2 Loosen...

Page 25: ...o need to perform load compensation If you have any standard device or you need to keep consistency in measured data perform load compensation The load compensation procedure is as follows 1 Fasten the electrode securing screws at the HIGH and LOW sides with load leads caught in the electrodes NOTE Do not fasten the screws too tightly to prevent the electrodes from damaged 2 Follow the instruction...

Page 26: ...g screws of both sides so that DUT leads are caught in the electrodes 2 Fasten both of the securing screws NOTE Do not fasten the screws too tightly to prevent the electrodes from damaged Figure 3 2 Performing DUT Measurement 3 Follow the instruction manual that came with your instrument to measure your DUT Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 27: ...e only characteristics of Z1 eliminating any effects from Z2 and Z3 1 Loosen the electrode securing screws of both sides and the screw of the guard terminal 2 Insert the leads No 1 or 2 into the electrodes then fasten the screws Insert the lead No 3 into the guard terminal then secure it with the screw Figure 3 4 Measuring 3 terminal device 3 Follow the instruction manual that came with your instr...

Page 28: ...ure only characteristics of Z2 eliminating any effects from Z1 and Z3 NOTE Connect your device to the guard terminal with a shortest possible lead Longer lead will degrade the guard effect resulting in less accurate measurement result Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 29: ...ntal Performance Characteristics This chapter provides specifications and supplemental performance characteristics of the 16047E test fixture Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 30: ...le DUT Type Lead components Frequency 110MHz DC Bias 42V peak max AC DC Operating Environment temp 20 C to 75 C humidity 15 to 95 RH wet bulb temp 40 C Non Operating Environment temp 40 C to 70 C humidity 90 RH wet bulb temp 65 C Dimension Approximately 135 W 40 H 65 D mm Weight Approximately 200g Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 31: ... below into the following equation Ze A Zs Zx Yo Zx 100 where A Additional Error Proportional Error Yo S Open Repeatability Admittance Zs Ω Short Repeatability Impedance Zx Ω Measured Value Impedance Without extension cable Applicable Instruments 4294A where f is the measurement frequency MHz Without extension cable Applicable Instruments 4192A 4194A 4263B 4268A 4278A 4279A 4284A 4285A 4338B where...

Page 32: ... measurement is calculated by additional error Ze of Z measurement as follows If Dx 0 1 De Ze 100 If 0 1 Dx 0 5 De Ze 100 1 Dx where Dx is the measured value of D It is necessary for Ze to be below 10 NOTE D is not expressed as a percentage but as an absolute value Yo 4 n 20 µ f 100 S Zs 4 m 1200 m f 100 Ω A 0 6 f 10 2 Yo 4 n 20 µ f 100 S Zs 4 m 1200 m f 100 Ω A f 5 MHz 0 6 f 10 2 f 5MHz 8 f 100 Y...

Page 33: ...ent is calculated by additional error Ze of Z measurement as follows If Dx 0 1 Rse Ze Dx If 0 1 Dx 0 5 Rse Ze Dx Dx is the measured value of D and is calculated as follows Dx 2 π f Csx Rsx where f measurement signal frequency Csx measured value of Cs Rsx measured value of Rs 1 Dx 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 34: ...0 Chapter4 Specifications and Supplemental Performance Characteristics Supplemental Performance Characteristics Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 35: ...31 5 Service This chapter provides information on servicing and proper maintenance Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 36: ...cial care when cleaning contacts To order parts use the Agilent Technologies part numbers listed in Table 1 1 and Table 1 2 If a faulty part is located in an assembly that cannot be disassembled order the next higher assembly or return the fixture to the nearest Agilent Technologies Sales Service Office for repair or replacement Replacable Parts Figure 5 1 Replacable Parts part 1 of 2 Artisan Tech...

Page 37: ... 6 16380 24001 4 TERMINAL 7 2950 0043 4 NUT 8 2190 0016 2 Washer 9 16047 09001 1 INSULATOR 10 16047 00625 1 SHIELD 11 16047 24022 1 SCREW 12 16047 00621 1 SHORT BAR 13 16047 04021 1 COVER 14 16047 60011 2 BNC LEVER ASSEMBLY 15 1250 1798 2 CONNECTOR BNC 16 16047 00626 1 CONTACT 17 16047 24023 2 SLEEVE 18 16047 00627 1 PLATE 19 0515 0999 2 SCREW Artisan Technology Group Quality Instrumentation Guara...

Page 38: ...34 Chapter5 Service Maintenance Figure 5 2 Replacable Parts part 2 of 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 39: ...047 04022 1 COVER 3 16047 24021 2 KNOB 4 16047 24026 2 FLANGE 5 0515 0914 4 SCREW 6 16047 01222 1 ANGLE 7 0515 0952 4 SCREW 8 0515 0999 3 SCREW 9 16047 25021 2 INSULATER 10 0515 2791 1 SCREW 11 16047 24025 1 SLEEVE 12 0515 0914 2 SCREW 13 16047 01221 1 ANGLE Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 40: ...36 Chapter5 Service Maintenance Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 41: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...