3
Do not plug in the 230 V mains plug
until you have completed installation and
checked the wiring after closing the
housing.
Attention! The telephone system must be
electrically earthed. Therefore connect
the Euro PE contact plug of the power
cable only to an expertly installed socket
(PE socket) to prevent danger to persons
and material.
Installation
Checking the scope of delivery ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
- 1 Telephone system with plugged-in
connection module
- 1 Set of securing material (3 dowels S6, 3
wood screws (cross head recess) 4 x 40)
- 1 Bolt (module extractor)
- 1 Comb element with 20 inscription
elements and 20 fit-on sleeves
- 1 ISDN connecting cable (IAE-IAE), 1.5 m
- 1 ISDN connecting cable (IAE-single wires)
- 1 PC connecting cable
- 1 Drilling template
- 1 Instruction manual
- 1 Installation manual
- 2 Short-form operating instructions for
system telephones
- 3 Short-form operating instructions
for a/b and ISDN terminals
- 8 Remote control cards
- 1 Set of 3.5" diskettes with the programs:
TK-Set, TK-Bill, TK-LCR TK-Phone and
TK-Timer.
Choosing a location ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
- The telephone system must only be in-
stalled in a dry room in which there are
no explosion hazards.
It must not be installed: in the proximity
of air conditioning systems. radiators, de-
vices that produce inadmissible interfer-
ence radiation, in locations that are sub-
ject to direct sunlight, in environments
containing excessive amounts of dust or
in locations where it may be splashed
with water or chemicals.
- Ambient temperature: 5°C to 40°C
- Humidity: max. 70% (no condensation)
- You must install the telephone system
vertically, with the connection side point-
ing downwards, on a firm and flat sur-
face.
- Minimum distance between the housing
and other limits above or below it: 50
mm.
- The distance between the telephone sys-
tem and the 230 V mains socket and the
IAE socket should not be more than 1 m
(mains lead approximately 1.2 m long).
For configuration via the serial PC / printer
interface (RS 232C), it must be possible to
place a laptop or a PC in the direct prox-
imity of the telephone system.
A separate circuit is recommended for the
telephone system’s 230 V mains power
supply.
Short-circuits caused by other domestic
appliances will then not have any detrimen-
tal influence on the telephone system.
Power consumption of the telephone
system: approximately 45 VA.
230 V power supply ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢