1 - 3

Installation

Checking the scope of delivery ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

- 1 Telephone system
- 1 Set of securing material (3 dowels S6, 3

wood screws (cross head recess) 4 x 40,
connection terminals)

- 1 ISDN connecting cable (IAE-IAE), 1.5 m
- 1 PC connecting cable
- 1 Drilling jig
- 1 Instruction package including instruction

manual, installation manual, short-form
operating instructions for system

telephones, short-form operating instruc-
tions for a/b and ISDN terminals, 8 remote
control cards

- 1 Set of 3.5" diskettes with the programs:

TK-Set, TK-LCR, TK-Bill, TK-Phone and TK-
Timer.

On our homepage "www.agfeo.de", you
may find the operating manuals for
download.

Choosing a location ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

- The telephone system must only be in-

stalled in a dry room in which there are
no explosion hazards.
It must not be installed: in the proximity
of air conditioning systems. radiators, de-
vices that produce inadmissible interfer-
ence radiation, in locations that are sub-
ject to direct sunlight, in environments
containing excessive amounts of dust or
in locations where it may be splashed
with water or chemicals.

- Ambient temperature: 5°C to 40°C

- Humidity: max. 70% (no condensation)

- You must install the telephone system ver-

tically, with the connection side pointing
downwards, on a firm and flat surface.

- Minimum distance between the housing

and other limits above or below it: 50
mm.

- The distance between the telephone sys-

tem and the 230 V mains socket and the
IAE socket should not be more than 1 m
(mains lead approximately 1.2 m long).

- For configuration of the PBX AS 140/190

via the serial PC / printer interface (RS
232C), it must be possible to place a
laptop or a PC in the direct proximity of
the telephone system.
The PBX AS 141/191 however, can be
configured by a PC with ISDN adapter via
the internal S0 bus.

Do not plug in the 230 V mains plug un-
til you have completed installation and
checked the wiring after closing the
housing.

Attention! The telephone system must
be electrically earthed. Therefore con-
nect the Euro PE contact plug of the
power cable only to an expertly installed
socket (PE socket) to prevent danger to
persons and material.

A separate circuit is recommended for the
telephone system’s 230 V mains power sup-
ply.
Short-circuits caused by other domestic ap-
pliances will then not have any detrimental
influence on the telephone system.

Power consumption of the telephone sys-
tem: approximately 30 VA (full load).

230 V power supply ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

Summary of Contents for basic-line plus AS 140

Page 1: ...1 1 Basic Line plus AS 140 AS 141 AS 190 AS 191 Installation...

Page 2: ...t and dis connect subscriber lines during a thunderstorm Lay subscriber lines in such a way that no one can step on them or stumble over them Prevent the ingress of liquid into the telephone system as...

Page 3: ...ax 70 no condensation You must install the telephone system ver tically with the connection side pointing downwards on a firm and flat surface Minimum distance between the housing and other limits abo...

Page 4: ...ket 2 Housing opened Feed in external MoH 3 5 mm jack Fig 1 Telecommunications system with the cover removed Pin strips with shorter pins are used in the telecommunications systems AS 140 AS 141 AS 19...

Page 5: ...otecting the telephone system s electrostati cally sensitive components Securing the housing Use the enclosed template to draw the three drill holes When drawing the drill holes make sure that there a...

Page 6: ...Relay for activating an external amplifier 100 Ohm termination S500 S501 External MoH only AS 190 AS 191 Connections of TAE La Lb W E b a a b E W Lb La 1 2 3 4 5 6 1 2 3 4 5 6 a1 b1 a2 b2 Internal S0...

Page 7: ...t IAE UAE socket are connected or the telephone system is not the last ISDN terminal on the point to multipoint connection By means of the connecting cable connect the ISDN telephone system to an ISDN...

Page 8: ...ly there In case you want to connect several ISDN terminals to the internal S0 plug you have to install an S0 bus with several sockets You connect this bus via a 4 wire screw clip You need the followi...

Page 9: ...rations Place the connecting leads through the housing openings Fit the screw terminals onto the connect ing leads Insert the screw terminals of the individual leads onto the provided slots see draw i...

Page 10: ...re bridged with a 1 kOhm 100 nF spark quenching combina tion Maximum contact load 30 VDC 1 A or 125 VAC 0 5 A ohmic load To feed in external music on hold connect the headphone output of an audio devi...

Page 11: ...s RS 232C interface to print out connection records For connection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as follows 9600 bau...

Page 12: ...an a b terminal with DTMF after installation The telephone system recognises the dial ling method in this way If you switch the dialling method on an a b terminal from DTMF to pulse dialling dial a d...

Page 13: ...l terminals Knocking protection off for terminals Transfer of phone numbers to the called party and the caller on Music on Hold MoH internal on Door call variant 1 day on no internal phone number ente...

Page 14: ...ondensation 230 VAC 10 10 50 Hz AS 140 8W Irated 100 mA 23 VA AS 141 15 W Irated 100 mA 23 VA AS 190 12 W Irated 130 mA 30 VA AS 191 20 W Irated 130 mA 30 VA approx 1 20 m System or multipoint connect...

Page 15: ...adphones output of a cassette or CD player 10 kohm asymmetrical max 100 mVpp 3 5 mm stereo jack AS 190 191 TFE interface FTZ 123 D12 pluggable by screw terminal AS 190 191 in place of a door handsfree...

Page 16: ...ions equipment 73 23 EWG Low voltage devices 89 336 EWG Electromagnetic compatibility This is why your telephone system bears the CE mark AGFEO GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http...

Reviews: