1 - 3
Installation
Checking the scope of delivery ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
- 1 Telephone system
- 1 Set of securing material (3 dowels S6, 3
wood screws (cross head recess) 4 x 40,
connection terminals)
- 1 ISDN connecting cable (IAE-IAE), 1.5 m
- 1 PC connecting cable
- 1 Drilling jig
- 1 Instruction package including instruction
manual, installation manual, short-form
operating instructions for system
telephones, short-form operating instruc-
tions for a/b and ISDN terminals, 8 remote
control cards
- 1 Set of 3.5" diskettes with the programs:
TK-Set, TK-LCR, TK-Bill, TK-Phone and TK-
Timer.
On our homepage "www.agfeo.de", you
may find the operating manuals for
download.
Choosing a location ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
- The telephone system must only be in-
stalled in a dry room in which there are
no explosion hazards.
It must not be installed: in the proximity
of air conditioning systems. radiators, de-
vices that produce inadmissible interfer-
ence radiation, in locations that are sub-
ject to direct sunlight, in environments
containing excessive amounts of dust or
in locations where it may be splashed
with water or chemicals.
- Ambient temperature: 5°C to 40°C
- Humidity: max. 70% (no condensation)
- You must install the telephone system ver-
tically, with the connection side pointing
downwards, on a firm and flat surface.
- Minimum distance between the housing
and other limits above or below it: 50
mm.
- The distance between the telephone sys-
tem and the 230 V mains socket and the
IAE socket should not be more than 1 m
(mains lead approximately 1.2 m long).
- For configuration of the PBX AS 140/190
via the serial PC / printer interface (RS
232C), it must be possible to place a
laptop or a PC in the direct proximity of
the telephone system.
The PBX AS 141/191 however, can be
configured by a PC with ISDN adapter via
the internal S0 bus.
Do not plug in the 230 V mains plug un-
til you have completed installation and
checked the wiring after closing the
housing.
Attention! The telephone system must
be electrically earthed. Therefore con-
nect the Euro PE contact plug of the
power cable only to an expertly installed
socket (PE socket) to prevent danger to
persons and material.
A separate circuit is recommended for the
telephone system’s 230 V mains power sup-
ply.
Short-circuits caused by other domestic ap-
pliances will then not have any detrimental
influence on the telephone system.
Power consumption of the telephone sys-
tem: approximately 30 VA (full load).
230 V power supply ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢