AGFEO basic-line plus AS 140 Installation Manual Download Page 13

1 - 13

As-delivered state

The followings settings are active in the 

as-

delivered state

:

- The switches S500 /S501 (termination for

the external S0 access) are closed and the
100 Ohm terminators are on.

- Line seizure: line seizure “0”
- Analog ports - internal phone numbers

(decade 1 set) and terminal types

AS 190

: 11 to 18,  telephone

AS 191

: 11 to 20,  telephone

AS 140

: 11 to 14,  telephone

AS 141

: 11 to 16,  telephone

- External access: unlimited for all users
- Call variant 1 (day): on, no internal phone

numbers entered, subscribers 11, 12 and
13 are called in the case of call

- Call variant 2 (night): off, no internal

phone number entered

- Call forwarding internal: off
- Number of calls: 5
- Don´t disturb: off for all terminals
- Knocking protection: off for terminals
- Transfer of phone numbers to the called

party and the caller: on

- Music on Hold (MoH): internal on
- Door call variant 1 (day): on, no internal

phone number entered, subscribers 11,
12 and 13 are called in the case of door
call

- Door call variant 2 (night): off, Printout of

dialed phone number: without

- Automatic dialing: off
- Printout of connection data set: off for all

users

- no internal phone number entered: ohne
- Cost limit: no entry
- Own tariff units factor: 0,12 DM
- Base factor (network operator factor):

0, 12 DM

- Cleardown at cost limit: off
- Setup code: off
- Cost code: no entry
- Switch box code: no entry
- Least Cost Router (LCR): off, for all sub-

scribers

- Busy on busy: off
-

AS 141, AS 191

: Transfer of “0” to dial

from call list at internal S0 port: off

AS 141, AS 191 with system telephone␣
ST 25

- Status display: off
- Cost display: off
- Display: German
- Call list: off

Summary of Contents for basic-line plus AS 140

Page 1: ...1 1 Basic Line plus AS 140 AS 141 AS 190 AS 191 Installation...

Page 2: ...t and dis connect subscriber lines during a thunderstorm Lay subscriber lines in such a way that no one can step on them or stumble over them Prevent the ingress of liquid into the telephone system as...

Page 3: ...ax 70 no condensation You must install the telephone system ver tically with the connection side pointing downwards on a firm and flat surface Minimum distance between the housing and other limits abo...

Page 4: ...ket 2 Housing opened Feed in external MoH 3 5 mm jack Fig 1 Telecommunications system with the cover removed Pin strips with shorter pins are used in the telecommunications systems AS 140 AS 141 AS 19...

Page 5: ...otecting the telephone system s electrostati cally sensitive components Securing the housing Use the enclosed template to draw the three drill holes When drawing the drill holes make sure that there a...

Page 6: ...Relay for activating an external amplifier 100 Ohm termination S500 S501 External MoH only AS 190 AS 191 Connections of TAE La Lb W E b a a b E W Lb La 1 2 3 4 5 6 1 2 3 4 5 6 a1 b1 a2 b2 Internal S0...

Page 7: ...t IAE UAE socket are connected or the telephone system is not the last ISDN terminal on the point to multipoint connection By means of the connecting cable connect the ISDN telephone system to an ISDN...

Page 8: ...ly there In case you want to connect several ISDN terminals to the internal S0 plug you have to install an S0 bus with several sockets You connect this bus via a 4 wire screw clip You need the followi...

Page 9: ...rations Place the connecting leads through the housing openings Fit the screw terminals onto the connect ing leads Insert the screw terminals of the individual leads onto the provided slots see draw i...

Page 10: ...re bridged with a 1 kOhm 100 nF spark quenching combina tion Maximum contact load 30 VDC 1 A or 125 VAC 0 5 A ohmic load To feed in external music on hold connect the headphone output of an audio devi...

Page 11: ...s RS 232C interface to print out connection records For connection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as follows 9600 bau...

Page 12: ...an a b terminal with DTMF after installation The telephone system recognises the dial ling method in this way If you switch the dialling method on an a b terminal from DTMF to pulse dialling dial a d...

Page 13: ...l terminals Knocking protection off for terminals Transfer of phone numbers to the called party and the caller on Music on Hold MoH internal on Door call variant 1 day on no internal phone number ente...

Page 14: ...ondensation 230 VAC 10 10 50 Hz AS 140 8W Irated 100 mA 23 VA AS 141 15 W Irated 100 mA 23 VA AS 190 12 W Irated 130 mA 30 VA AS 191 20 W Irated 130 mA 30 VA approx 1 20 m System or multipoint connect...

Page 15: ...adphones output of a cassette or CD player 10 kohm asymmetrical max 100 mVpp 3 5 mm stereo jack AS 190 191 TFE interface FTZ 123 D12 pluggable by screw terminal AS 190 191 in place of a door handsfree...

Page 16: ...ions equipment 73 23 EWG Low voltage devices 89 336 EWG Electromagnetic compatibility This is why your telephone system bears the CE mark AGFEO GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http...