Section I: Imagesetter
Diagnostics
3-33
2.
The “T-Compress Speed” is really the compression speed for both supply
and take-up servo motors. The supply servo uses a percentage of the “T-
Compress Curr” value. The percentage amount is specified in the “S Cmp
Curr Rtio” field, which has a default of 50 (50%). So if:
T-Compress Curr = 24
T-Compress Speed = 6
S Cmp Curr Rtio =
50
Then the take-up servo runs at a speed of 6 and a current of 24. The sup-
ply servo runs at a speed of 6 and a current of 12.
NOTE:
The above values may be different depending on the revi-
sion of software in your system. Refer to the Customer Ser-
vice Bulletin (CSB) for the correct values for that revision of
software.
Write new values to the imagesetter by typing in the appropriate parameter. Listed
below are the media parameters, ranges and definitions.
Media Parameter
Range
Definitions
Supply Motor Feed Current
(0 - 255)
Current of supply motor during feed.
Supply Motor Comp Current
(0 - 255)
Current of supply motor during compression.
Supply Motor Comp Speed
(0 - 255)
Speed of supply motor when going into compression.
Supply Feed Speed
(0 - 255)
Speed of supply motor during feed.
Supply Hold Speed
(0 - 255)
Supply hold speed for punchless systems.
Supply Hold Current
(0 - 255)
Supply Hold Current for punchless systems.
Supply Rewind Current
(0 - 255)
Current of supply cassette motor during rewind.
Supp/Tkup Delay*
0 - 100 take-
up motor
starts before
supply motor
101 -200
supply
motor before
servo
The start-up delay time between the take-up servo and
supply servo motors. Default is 0 (zero), which indicates
that the delay time parameter is not being used.
Media Settle Delay
(0 - 999)
Settling time of media.
Nip Delay
(0 - 100)
Delay after Nips are open/closed.
Image Feed Length
(0 - 3600)
Image feed length from AVDIAG.
S-Spind Fwd Assist
The supply spindle forward assist current, which is the
amount of current applied to the supply cassette revind
motors in the forward direction. Used at the beginning of
all supply and image feeds. Default is 50 (fifty)).
Summary of Contents for Avantra 36/44
Page 1: ...The Avantra 36 44 Service Manual Part Number 580078 0002 ...
Page 24: ...Section I Imagesetter ...
Page 282: ...Section II Bridge ...
Page 327: ...Section III Buffer ...
Page 359: ...Section IV On line Processor ...
Page 462: ...Avantra 36 44 Service Manual B 2 Spare Parts Avantra 36 44 OLP Parts ...
Page 464: ...Avantra 36 44 Service Manual B 4 Spare Parts Avantra 36 44 OLP Parts ...
Page 466: ...Avantra 36 44 Service Manual B 6 Spare Parts Avantra 36 44 OLP Cassette Parts ...
Page 468: ...Avantra 36 44 Service Manual B 8 Spare Parts Avantra 36 44 OLP Feed Rack Parts ...
Page 470: ...Avantra 36 44 Service Manual B 10 Spare Parts Avantra 36 44 OLP Tank Parts ...
Page 472: ...Avantra 36 44 Service Manual B 12 Spare Parts Avantra 36 44 OLP Right Side View Parts ...
Page 474: ...Avantra 36 44 Service Manual B 14 Spare Parts Avantra 36 44 OLP Control Panel Parts ...
Page 476: ...Avantra 36 44 Service Manual B 16 Spare Parts Avantra 36 44 OLP Rack Spare Parts ...
Page 478: ...Avantra 36 44 Service Manual B 18 Spare Parts Avantra 36 44 OLP Dryer Spare Parts 18 ...
Page 480: ...Avantra 36 44 Service Manual B 20 Spare Parts Electronics upper Spare Parts ...
Page 482: ...Avantra 36 44 Service Manual B 22 Spare Parts Electronics lower Spare Parts ...
Page 484: ...C 1 Appendix C Wiring Diagrams ...
Page 491: ...Section V Crane ...