Agelkom CAP04-V Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
  
 
 
 

69 mm dia

.

 

47 mm dia

.

 

67mm approx

.  

Mounting Details 

Summary of Contents for CAP04

Page 1: ...ly low 15V level during in active and drive up to 15mA These outputs can directly drive LED or Opto Coupler Due to current limiting there is no need voltage divider for 12 and 5 volts input range of y...

Page 2: ...sor and observe down output is activated in your HOME position or sufficiently high above the plate If DOWN LED is activated instead of UP readjust the core of the coil 3 Start slowly to decrease the...

Page 3: ...cutting material Turn CW until TOUCH LED is ON APPLICATION During plasma cutting sensor ring and plasma torch are in the same height This will allow to use TOUCH output as a collision detection means...

Page 4: ...ined input BLUE 0V 7 8 GREY HEIGHT V PINK HEIGHT V To PC Port 2 pin Spindle Output Analog Out 0 10VDC Narrow Wide TOUCH ADJUSTMENT CCW Turn off the LED DOWN IN POS UP TOUCH CABLE SENSOR HEAD BNC CONNE...

Page 5: ...at 15V and 15mA Check your input and configure for ACTIVE HIGH Your inputs must be 0V level and Pull Up resistor not used If your BREAKOUT BOARD has OPTO COUPLER inputs at 5V level you can connect di...

Page 6: ...ly broken Use plastic screw driver It is not a SESITIVITY adjustment Smoothly close some metal plate say 20cm x 20cm to sensor ring and observe that voltage increase never decrease come to closer 1 HE...

Page 7: ...ype Ground Connection Use thick wire 10mm GROUNDING MOUNTING Dimensions are in mm Case Size 116 65 31 Two mounting holes are shown in red Machine Chassis CW Coil Fully CCW Sensig Height Down Led is ON...