Agelkom CAP04-V Manual
4
Technical Specifications:
Supply: Nominal 24VDC 100mA, Max: 30VDC Min: 18VDC
Current: Less than 100mA
Protection: Against supply reverse voltage.
All Outputs: Normally high at 15V, 15mA with current limiter resistor.
Can be drive opto-coupler directly
Sensor Cable: 90cm Length, Type RG59
WHITE IN POSITION
BROWN TOUCH
4
SENSOR POWER +24VDC
SENSOR POWER 0V
5
3
2
1
AGELKOM
CAPACITIVE
SENSOR
CAP04 V
CABLE COLORS
RED + 24v
GREEN DOWN
YELLOW UP
CONNECTOR
PIN NUMBER
Simplified typical connection of CAP04-V shown below.
CABLE SHIELD
POWER SUPPLY / SYSTEM GROUND
Breakout Board
To PC, Port 2, pin # “Torch Down input”
To PC, Port 2, pin # “Torch Up input”
To PC Port Ground
I/O board
User defined PC Port# and pin#
6
To PC Port 2, pin # “Probe input”
To PC, Port 2, pin # “User Defined input”
BLUE 0V
7
8
GREY HEIGHT V
+
PINK HEIGHT V
-
To PC Port 2, pin # “Spindle Output”
Analog
Out
0-10VDC
Narrow
Wide
TOUCH
ADJUSTMENT
CCW Turn-off
the LED
DOWN
IN POS
UP
TOUCH
CABLE
SENSOR HEAD
BNC
CONNECTOR
SENSOR
ADJUSTMENT
COIL
Adjust 1 volt
at Orange bead
GAP
ADJUSTMENT
8 PIN
CONNECTOR
Connect DVM
for COIL adj.
Common Point
for Adjustment
Black bead
Connect DVM
Height / Voltage
Adjust 10V (white bead)
at 10V Control Input
10V(white bead)
Test Point
PWM Disable
Jumper
Height Control Input is floating
against ground loop problem.
Adustment procedure as follows:
Apply these input 10VDC and adjust
trimmer potentiometer until to read at
WHITE BEAD about 10V. Reduce
control voltage about 3 volts and
measure 13.67V at same test point.
Between 0 to 3Volts, controlling is
disabled for the noise margin.
If no voltage applied, the same voltage
appear about 13.67V. This is the
Maximum Height Level
All adjustment made at factory. Please
do not change until it is necessary.