8
Wiring Installation
– 600A1
Connecting to the Baler Harness
Locate the communication harness (006-
6650VC) and the connection point shown (Left)
on baler.
Under the chamber locate the Active Terminator from the
end of the baler harness. It is located at the right rear corner
of the baler frame. Attach Baler Interface Harness
(006-6650VC) to that location. Reconnect Active Terminator
to open port of that same harness (006-6650VC). If your
baler does not have a Terminator at this location see further
instructions below.
If your baler has the White Terminating Resistor you will
need to attach the Pre 2012 AGCO Integration Harness
(006-6650VAX) to the end of the Baler Interface harness
(006-6650VC). Please contact Harvest Tec for this harness.
This style terminator may be next to the Baler’s Main
Processor.
Be sure to mount and secure all harnesses away from
hydraulic lines and moving parts.