background image

5

Slower-blinking LEDs are an out-of-beam indication (receiver has moved
beyond the reception range). The LED arrows show the direction to move
the bucket to pick up the laser beam again.

To turn off the receiver, hold the On/Off key for 3 seconds and release.
If the MR240 does not receive any signal for an hour, it will shut off auto-
matically.

The receiver uses 3 AA alkaline bat-
teries. Unscrew black cap at bottom
of unit to replace batteries; orient as
shown. Operating time is approxi-
mately 130 hours. 

The low battery LED near base of
receiver will be lit when there are
about 8 hours remaining.

4. Power

LEDs indicate grade direction: 

the blinking LEDs point in the

direction to move the bucket to reach grade. 

3 - CHANNEL MODE

5 - CHANNEL MODE

4

3. Using the MR 240

Coarse

3 channels

Fine

3 channels

Fine

5 channels

Back to Coarse

3 channels

Press red On/Off key at the top of receiver to turn it on. 

Changing deadband settings 
(fine and coarse)

LEDs blink momentarily to indicate the setting: deadband (fine or
coarse accuracy) and channels. The last setting used stores in
memory and is the default when turned on.

Pressing On/Off will change the setting, in this sequence:

LED indicators

On/Off switch;
also changes 
deadband setting

Back plate with 
strong magnets; 
attaches to machine

On-grade
alignment notch

Magnet release lever

3 AA batteries

Above grade

On-grade

Below grade

Low battery

High or

Beam

Lost

On

Grade

Low or

Beam

Lost

High or

Beam

Lost

Near

grade

high

On

Grade

Near

grade

low

Low or

Beam

Lost

MR240  14/08/07  12:59  Page 4

Summary of Contents for MR 240

Page 1: ...Operating Manual MR 240 Receiver MR240 14 08 07 12 59 Page 1...

Page 2: ...late while mounting the receiver on your machine 1 Precautions for safe operation The MR 240 receiver offers accurate grade information for all visual machine control applications with 230 detection o...

Page 3: ...e direction to move the bucket to reach grade 3 CHANNEL MODE 5 CHANNEL MODE 4 3 Using the MR 240 Coarse 3 channels Fine 3 channels Fine 5 channels Back to Coarse 3 channels Press red On Off key at the...

Page 4: ...position when grade readings are taken Position the receiver s on grade notch at the top of this L measurement per the following attachment instructions 5 Setup for excavating 6 Positioning the MR 240...

Page 5: ...e whether to repair or exchange the product The only obligation and sole recourse of the buyer will be limited to this repair or exchange The manufacturer the distributor or the retailer will in no ca...

Page 6: ...pendant le transport 1 S curit Le MR 240 vous garantit une extr me pr cision dans l estimation des hauteurs dans toutes les applications de guidage d engins en visuel et ce avec un angle de r ception...

Page 7: ...ux Large nouveau 3 canaux Un clignotement lent signifie que le rayon se perd l ext rieur de la zone de r ception Les fl ches lumineuses indiquent la direction imprimer la pelle pour r cup rer le rayon...

Page 8: ...ant est qu il se trouve dans la m me position que lors de l talonnage de r f rence Positionner le cran de r cep tion l extr mit sup rieure de la mesure L 5 Montage sur excavatrice 6 Positionnement du...

Page 9: ...areil En cas de r exp dition pri re d utiliser l emballage original L obligation de faire r viser r guli rement l appareil soit directement par le fabricant soit par un atelier agr par lui incombe au...

Page 10: ...transporte 1 Seguridad El MR 240 le garantiza una gran precisi n en la determinaci n de alturas en todas las aplicaciones utilizadas en las maquinarias de obra controladas visualmente todo con un ngu...

Page 11: ...la pala para recuperar el haz Para apagar el receptor basta con pulsar el interruptor de encendi do apagado durante aproximadamente 3 segundos En ausencia de cualquier se al durante una hora seguida...

Page 12: ...que en el momento de la graduaci n de referencia Sit e la muesca de recepci n en el extremo superior de la medida L 5 Montaje sobre excavadora 6 Posicionamiento del MR 240 Antes de conectar el recept...

Page 13: ...o de reexpedici n utilice el empaque original La obligaci n de revisar regularmente el aparato sea directamente por el fabricante o por un taller concertado por este corresponde nica mente al usuario...

Page 14: ...com For Asia Agatec Asia Pacific Primtools 3B EIB Center 40 44 Bonham Strand Sheung Wan Hong Kong info primtools com www agatec com 852 852 2566 3667 Fax 852 2566 9968 For all other countries Agatec...

Reviews: