Agatec AGATEC220 User Manual Download Page 7

11

10

GB F E D I N FIN 

4.2.3  Checking Y axis

1.

Rotate the laser 90 degrees so that Y’ is facing the wall. 

2.

Mark the location of the center of the beam.

3.

Rotate the laser 180 degrees so that Y faces the wall.

4.

Mark the location of the beam center near the first mark.

5.

At 100 ft., the marks should be no more than 1/4" apart 

(at 30m, no more than 6 mm apart). This is within the stated 
accuracy of ± 1/8” at 100 ft. (± 0.010%).

6.

If the marks are close enough, Y axis is within calibration. 

Proceed to “Final X to Y Check.” If the marks are not close enough,
Y axis needs to be calibrated.

4.2.4 Calibrating Y axis

The laser must be calibrated to bring the beam to the center of the
two Y marks.
If you are still in calibration mode from the X axis, turn Y towards
the wall and press the H.I. key to change to the Y axis. When the Y
LED blinks slowly, it’s ready to be calibrated in Y axis.

If you’re no longer in calibration mode

1.

Turn off the laser. 

2.

Hold the MAN (5) key. While holding, momentarily press the ON key.

3.

After the LEDs blink in sequence, release the MAN (5) key. 

4.

Select the Y axis by pressing the HI key on the laser keypad 

(on the remote, press the double arrow key >>l ). 

5.

Y LED will blink rapidly, indicating leveling. When the LED blinks

slowly, the laser is ready to calibrate. 

6.

If you have not moved the laser, use the Y marks made in previous

steps of “Checking Y axis”. 

7.

Use arrows on the keypad to move beam up or down to the

halfway mark. If the Y axis is toward the wall with the marks, 
use the ^ key (8) to raise beam, and the v key (9) to lower beam. 

8.

Press MAN key (5) to save the calibration you’ve just made on Y

axis. (On remote, use key with the small dot).

If you are not sure of the calibration, don’t save it and turn the laser
off using the On/Off key.

2.

Turn on the laser.

3.

Mark the location of the center of the beam. If it’s too bright to

see the beam, use the detector.

4.

Rotate the laser 180 degrees so that X faces the wall.

5.

Mark the location of the center of the beam near the first mark

so that both marks are in line, one above the other.

6.

At 100 ft., the marks should be no more than 1/4" apart 

(at 30m, no more than 6 mm apart). This is within the stated 
accuracy of ± 1/8” at 100 ft. (± 0.010%).

7. 

If the marks are close enough, X axis is within calibration. The

second axis Y must then be checked (see later section).
If the marks are not close enough, the X axis needs to be calibrated.

4.2.2 Calibrating X axis

The laser must be calibrated to bring the beam to the center of the
two X marks. Read "Calibration Overview" before proceeding.

1.

Turn off the laser. 

2.

Hold the MAN (5) key. While holding, momentarily press the

ON key. 

3.

After the LEDs blink in sequence, release the MAN (5) key. 

4.

X LED will blink rapidly, indicating leveling. When the LED

blinks slowly, the laser is ready to calibrate. 

5.

If you have not moved the laser, use the X marks made in 

previous steps of “Checking X axis”. 

6.

Use arrows on the keypad to move beam up or down to the

halfway mark. If the X axis is toward the wall with the marks, use
the ^ key (8) to raise beam, and the v key (9) to lower beam. 

7.

After completing the X calibration, press the H.I. key (3) to

change the axis and to calibrate the Y axis. (On the remote, press
the double arrow key >>l) 

8.

If the Y axis doesn’t have to be calibrated, press MAN key (5)

to save the calibration you’ve just made on X axis. (On remote, use
key with the small dot.) 

If you are not sure of the calibration, don’t save it and turn the
laser off using the On/Off key. 

GAT220-08-2007  7/10/07  22:38  Page 10

Summary of Contents for AGATEC220

Page 1: ......

Page 2: ...Safety The GAT220 is a Class 3R laser manufactured to comply with the international rules of safety IEC 60825 1 2001 Although the power of the emission of the beam is less than 5mW in Class 3R the fo...

Page 3: ......

Page 4: ...lf level ing After it has leveled the head will start to rotate 3 To select the H I Alert press the H I key 3 The H I Alert func tion will be active 30 seconds after the GAT220 has finished its self l...

Page 5: ...pe 6 Press the MAN key to return to automatic mode CAUTION In manual mode the beam rotates even if the laser is not leveled The H I Alert function is not available when the unit is in manual mode When...

Page 6: ...calibrate using the non rotating point If it s too bright to see the beam you ll use the detector and will need to have the beam rotating When you re in calibration mode press the rotation key 7 on th...

Page 7: ...to change to the Y axis When the Y LED blinks slowly it s ready to be calibrated in Y axis If you re no longer in calibration mode 1 Turn off the laser 2 Hold the MAN 5 key While holding momentarily p...

Page 8: ...apacity The GAT220 laser is guaranteed to be free of manufacturing defects for a period of one year Any abnormal usage or if the instrument has been subjected to shock will void this warranty Under no...

Page 9: ...erence an up arrow move it up When a horizontal line appears on the display the detector is at the same level as the laser beam 5 Press the On Off key to turn the detector off It will automatically sh...

Page 10: ...n m ar a Niveau Electronique...

Page 11: ...plications de nivellement 1 2 Avertissement Le GAT220 est un produit laser de Classe 3R laser Il respecte la norme de s curit internationale IEC 60825 1 2001 Bien que la puissance d mission du laser n...

Page 12: ...tale 1 Le GAT220 peut tre utilis m me le sol ou sur un tr pied standard 5 8 11 2 Appuyer sur la touche On Off 1 L instrument se met a niveau automatiquement 3 Pour s lectionner le mode Tilt appuyer su...

Page 13: ...ique Le mode semi automatique signifie L axe Y est en mode manuel L axe X est en mode automatique Il vous est donc possible de faire une pente manuelle sur l axe Y en utilisant les touches 8 et 9 du c...

Page 14: ...llule de r ception si la visibilit le permet Ou arr ter la rotation et diriger le point laser manuellement vers le mur 4 Faire pivoter le laser de 180 Lorsque le laser s est recal marquer la position...

Page 15: ...u sur la touche 9 pour descendre le rayon au niveau du milieu des 2 marques 7 Enregistrer les donn es de l axe Y en appuyant sur la touche MAN 5 du clavier Si une erreur a pu se produire lors des op r...