AGA VENTILATION HOOD Instruction & Installation Manual Download Page 7

5

If your installation has been roughed-in (including
ductwork and wiring), be certain there are no obstructions
in the way of the mounting, pipes, or other wiring, etc.

If the installation has not been roughed in, check what is

needed to create the framing and mounting hardware
(allthreads, nuts, etc.). Be sure the location will not
interfere with wiring, other utilities, or structural
considerations.

1. Use 2x4s, Unistrut or Angle Iron, to construct the
framing. The considerable weight of the hood makes
this necessary.

2. Mark the center location of the hood. Install two
2x4s (wide side down), Unistrut or Angle Iron, across
ceiling joists with outer edges aligned with the existing
ceiling joist.

3. Drill two 7/16” diameter holes in the 2x4s, Unitstrut
or Angle Iron, the same distance apart as the nuts in
the top of the hood,plus the finished drywall thickness.
This ensures the hood is tightly fitted against the wall.
Install wooden spacers if necessary to ensure the top
of the hood is flush with the ceiling.

4. Insert all four of the allthread bolts into the top of
the hood. (Approximately 3”)

5. While lifting the hood, guide and position the
allthread bolts through the 2x4s, Unistrut or Angle
Iron. (At least 2 peopleare recommended for this
step.)

6. Secure the hood with 3/8” nuts (do not tighten).

7. Adjust hood to proper location and tighten nuts. A
second nut should be used as a locknut to prevent
vibration and ensure stability.

8. Connect the duct to hood using 3 sheet metal
screws and seal all joints with silicone or duct tape.
Use care when fastening ductwork to transition.
Position screws such that damper assembly can open
and close.

9. Make electrical connections.(An electrical
contractor should make all electrical connections. See
wiring diagram.)

Method 1: Ventilation Hood - Ceiling Mounted

There are several different methods available to
mount the hood: The Ceiling Mount, The Wall Mount
and the Rough-In Plate Mount.

For installation questions, Please dial:

1-877-650-5775

Installation Methods

Check the Installation Location

Choose the Installation Method

2x4s or unistruts

hood

duct

attachment

allthread bolts

Top view

existing ceiling joists

Summary of Contents for VENTILATION HOOD

Page 1: ... and lock out the service disconnect switch to prevent power from being switched on accidentally When the service disconnect switch cannot be locked securely fasten a prominent warning device such as a tag to the service panel Record the model and serial numbers before installing the Aga ventilation hood Both numbers are listed on the rating plate located on the left wall of the hood shell Model N...

Page 2: ...nguisher ONLY IF a The fire department has been contacted b You know you have a Class ABC extinguisher and you know how to operate it c The fire is small and contained in the area where it started d You can fight the fire with your back to an exit For general ventilating use observe the following 1 Local building codes may require the use of make up air Consult your local HVAC professional for spe...

Page 3: ... Mounted 6 Method 3 Ventilation Hood Rough In Plate Mounted 6 Installation Assembly 7 Rough in Plate Mount Installation 7 Mounting the In Hood Fan 8 Ducting Connection 8 Electrical Connection 9 Installation of Hood Unit 9 Installation of Grease Troughs Filters Lamps 10 Use and Care 10 Wiring Diagram Ventilation Hood 11 Ventilation Hood Customer Warranty 12 Ventilation Hood Table of Contents ...

Page 4: ...re ready to hang it Do not store the hood anywhere other than within the carton If it is necessary to remove your hood from the carton arrange it on a blanket or padded area that will protect your hood from scratches or indentations To lift hood place your fingers under the lower reveal of the hood Grasp firmly and lift Caution Due to the size and weight of this unit two installers are recommended...

Page 5: ...ly Center or custom made by your local sheet metal shop square rain caps require equivalent cross sectional area to 10 diameter ducting Vent Hood must be vented outdoors Do not exhaust air into spaces within walls ceilings attics crawl spaces or garages where an accumulation of grease could become a fire hazard Materials and installation must be completed in accordance with all local national code...

Page 6: ... for 36 Models 10 Transition for 48 Models Included 18 46 cm Vent Hood 30 to 36 92cm 0 Clearance to Sides 4 AGA AGA Overall Dimensions INSTALLING HOOD AT TOP AGA 5 INSTALLING HOOD FROM REAR ELECTRICAL INLET 36 48 WIDTH 2 1 2 24 FRONT TO BACK 18 HEIGHT 12 UPPER REVEAL DEPTH 20 3 4 Dimensions CENTER LINE ...

Page 7: ... hood is flush with the ceiling 4 Insert all four of the allthread bolts into the top of the hood Approximately 3 5 While lifting the hood guide and position the allthread bolts through the 2x4s Unistrut or Angle Iron At least 2 peopleare recommended for this step 6 Secure the hood with 3 8 nuts do not tighten 7 Adjust hood to proper location and tighten nuts A second nut should be used as a lockn...

Page 8: ...nuts do not tighten 7 Adjust hood to proper location and tighten nuts A second nut should be used as a locknut to prevent vibration and ensure stability 8 Locate studs and drill 3 8 diameter holes through back panel Secure hood to wall with four 1 4 x1 1 2 lag screws 9 Connect the duct to hood using 3 sheet metal screws and seal all joints with silicone or duct tape Use care when fastening ductwor...

Page 9: ...and align with the center of the soffit Install rough in plate to the soffit using four screws packed with the plate These screws must be driven into the soffit framing Use the rough in plate assembly to determine the location of wall studs Position the rough in plate in the desired location and mark the predrilled holes on the wall Secure the back side of the rough in plate to the wall stud If ne...

Page 10: ...y Molex Plug Studs Nuts 6 used for fan mounting 8 Ducting Connection For 36 Hoods use 8 round duct from the transition For 48 Hoods use 10 round duct from the transition The length of ducting should be as short and straight as possible for best performance of fan SEAL ALL JOINTS WITH DUCT TAPE Transition 30 to 36 30 to 36 rough in plate rough in plate 8 or 10 round duct wall cap hood hood lag scre...

Page 11: ...weld studs on the rough in plate with the slotted holes on the back of the unit Using the hex nuts provided secure the hood assembly to the rough in plate Installation of Hood Unit 2 x 4 Framing 1 2 Thick Drywall Screw Hood Front Power Supply Junction Box located inside of Rough In Plate To Remote Fan if used Fan Motor Assembly Fan Plate Keyhole Molex Plug Connector Soffit Molex Plug Connector Mou...

Page 12: ...d speeds on the control panel correspond with fan speed Cooktop Lighting The halogen lights are controlled with one ambiant and brilliant switch To use the lights on brilliant setting push the switch up For ambiant setting push the switch down Use only R20 size halogen 50 Watt bulbs Use and Care Replacement Parts For purchasing replacement parts contact your dealer Filters Wash filters frequently ...

Page 13: ...EE DETAIL BLUE BLACK RED WHITE 6 PIN CONNECTOR 5 3 1 2 L1 FAN SWITCH 5 BLACK 21 BLACK WHITE HI HEAT THERMOSTAT 1 2 3 BLACK 17 9 NC 200F NC 200F TERMINAL BLOCK WHITE BLACK GREEN 18 9 5 G L1 N HALOGEN LIGHT 2 LIGHT UNIT RIGHT 1 WHITE 11 YELLOW 2 LIGHT UNIT LEFT HALOGEN LIGHT YELLOW WHITE 1 11 LIGHT SWITCH DIODE 11 1 2 3 WIRING DIAGRAM VENTILATION HOOD 8 BLACK BLACK 14 1 11 HALOGEN LIGHT WHITE YELLOW...

Page 14: ...ge hood or from service delays beyond their reasonable control 4 To obtain warranty service the original purchaser must present the original Bill of Sale Model and Serial number Components repaired or replaced are warranted through the remainder of the original warranty period only 5 The warranty does not cover expense involved in making this appliance readily accessible for servicing Labour costs...

Reviews: