Electrical Connection
Run power cable to installation location. Remove wiring cover,
install wire clamp, insert cable in hood through wire clamp and
secure by tightening the wire clamp.
Connect cable into wiring box, located on rough-in plate, using
wire nuts.
Connect wires as follows:
BLACK
wire to power supply
BLACK
wire.
WHITE
wire to power supply
WHITE
wire.
GREEN GROUND
wire under
GROUND
screw.
Reinstall wiring cover.
Install the hood unit to the rough-in plate by aligning the weld
studs on the rough-in plate with the slotted holes on the back of
the unit.
Using the hex nuts provided, secure the hood assembly to the
rough-in plate.
Installation of Hood Unit
2” x 4”
Framing
1/2” Thick
Drywall
Screw
Hood
Front
Power
Supply
Junction Box
located
inside of
Rough-In
Plate
To Remote Fan
(if used)
Fan Motor
Assembly
Fan Plate
Keyhole
Molex Plug
Connector
Soffit
Molex Plug
Connector
Mounting
Holes
9
IMPORTANT NOTE: If additional support is required, drill
supplementary mounting holes in the rough-ins plate and use
these holes to attach the hood assembly to the wall framint
CAUTION
Due to the weight of the hood, be
sure to have adequate manpower
for installation.