AGA Rangemaster FM900 Installation, Operation And Maintenance Instructions Download Page 2

 

FM900 Built In Extractor 

 

 

Installation, Operating & Maintenance Instructions 

 

 

W0645 Aga Rangemaster FM900 (energy label version) O&M Jan 15.docx

             P

age 2 

AGA Rangemaster

 

 

taut over straight runs to ensure that the internal surface is 
as smooth as possible. 

  If  using  rigid  ducting  we  recommend  that  the  initial  duct 

connection to the extractor spigot is made using semi-rigid 
round ducting to allow for any positioning errors and easy 
disconnection in the event of maintenance. 

4.  INSTALLATION 

The FM range of built in extractors are designed to slot into a 
cut-out/opening  made  in  a  horizontal  soffit  panel  (usually  the 
underside  of  kitchen  furniture  or  inglenooks/chimney 
arrangements). 

 

A panel thickness of at least 15mm must be provided into 
which an opening can be made and the unit fixed.

 

4.1.  Prepare Opening 

Prepare  an  opening  where  the  extractor  is  to  be  installed. 
Detailed  dimensioned  drawings  showing  the  extractor  layout 
can be found in Section 8 "

General Arrangements Drawing"

 to 

help you with this

.

 

4.2.  Duct Installation 

Make  holes,  as  necessary,  in  the  walls  or  ceiling  to  take  the 
ducting  from  the  extractor  exhaust  spigot  location  to  the 
outside.

 

Note:

 A 175mm diameter hole is suitable for both ducting and 

any electrical cables (such as power or remote fan cables) to 
pass through. 

Depending  upon  your  installation  you  may  need  to  run  the 
ducting  before  or  after  the  extractor  is  in  place,  however,  all 
holes  must  be  made  in  advance  to  avoid  debris  entering  the 
appliance. 

The duct route length should be kept as short as possible with 
as few bends as possible (see Section 3). 

If  terminating  on  an  outside  wall  a  suitable  weather  louvre 
should  be  fitted.  A  variety  of  ducting  components  and 
complete kits are available to suit most installations. 

For  roof  or  chimney  duct  terminations  please  contact 

Aga 

Rangemaster

 or seek alternative specialist advice. 

 

Recirculating Models 

We  do  not  recommend  recirculating  air installations  and  they 
should be avoided wherever possible (see section 3). 

If  your  extractor  has  been  adapted  for  recirculation  (not  the 
standard  configuration)  then  adequate  provision  must  be 
made  for  exhausted  air  to  return  into  the  kitchen  (at  least 
equivalent  to  125mm  diameter  round  duct)  -  e.g.  ducted  out 
through the top of the cabinet. Failure to do so may cause the 
unit to overheat and fail and will invalidate your warranty. 

4.3.  Electrical Installation 

 

The  extractor  is  a  stationary  appliance  designed  to  be 
connected by fixed wiring to the electrical supply. A competent 
electrical technician must perform the electrical installation. 

The  hood  must  be  fed  from  a  dedicated  230Vac  single 
phase  electrical  supply

  terminated  with  a  switched  spur 

fitted with a  3A  fuse.  The spur should  be located adjacent  to 
the hood/cooker so that the supply can be disconnected from 
the  hood  using the  switch.  The  means  of  disconnection  from 

the supply  must  have  a  minimum  contact separation  of  3mm 
in  all  poles.  Alternatively,  a  means  of  disconnection  in  the 
fixed  wiring  according  to  the  relevant  wiring  rules  must  be 
fitted. 

For your convenience you may wish to terminate the electrical 
supply from the switched, fused spur with a standard UK 3 pin 
240V  socket  positioned  close  to  the  extractors  intended 
location. 

The  extractor  can  then  be  fitted  with  a  standard  240V  3  pin 
plug so that it can be plugged in to the switched supply by the 
appliance installer. 

Should  you  wish  to  wire  the  appliance  directly  into  the 
switched,  fused  spur  then  a  supply  cord  for  connecting  the 
spur  to  the  extractor  is  included.  The  mains  supply  is 
connected to the free end of this cord as follows: 

INCOMING SUPPLY CORD CONNECTIONS

 

Core

 

Core Colour

 

Live 

Brown 

Neutral 

Blue 

Protective Earth 

Green/Yellow 

4.4.  Connecting the Ducting 

Terminate  the  ducting  where  it  exits  the  building.  If  using  a 
wall  mount  weather  louvre  secure  the  ducting  to  the  louvre 
spigot and attach the louvre to the wall. Ensure that the air fins 
are  directed  downwards.  If  you  are  fitting  an  alternative 
termination ensure that the ducting is secure. 

If using expanding foam make sure that any flexible ducting is 
supported internally to prevent it crushing where foamed. 

Pull  flexible  ducting  back  along  its  route  such  that  it  is  as 
smooth  as  possible.  Position  the  extractor  face  down  and as 
close to the opening as is practical and cut off excess before 
connecting  the  ducting  to  the  extractor  exhaust  spigot  using 
plastic tie straps or a suitable alternative (e.g. jubilee clip) - do 
not use duct tape as the sole means of connection. 

Note: The  FM900  has  integral  non-return  flaps  as part  of  the 
spigot assembly to reduce air blowing back into the unit from 
outside.  Take  care  not  to  obstruct  these  flaps  when 
connecting  flexible  ducting.  The  flaps  are  designed  to 
supplement  the  provisions  you  make  in  your  ductwork  to 
prevent  draughts.  You  may  remove  these  flaps  if  you  are 
concerned they will catch on your ductwork provided that other 
measures to control draughts have been installed. 

Check that the duct has not been flattened or kinked. 

4.5.  Fixing the Extractor in Position 

  Fixing the extractor safely into position requires two people 

so do not start if assistance is unavailable. 

  Remove  the  grease  filters  as  described  in  Section  6  to 

prevent damage whilst manoeuvring the product. 

  Fixing holes are located in the extractor fixing flange – see 

Section 8 

"General Arrangements Drawing".

 The extractor 

is  held  securely  in  place  by  screws  into  the  soffit  panel 
through these holes. 

  Check  that  the  electrical  supply  chord  has  been 

connected, that power is switched off and that the ducting 
is securely fastened to the spigot. 

  Push  the  extractor  up  through  the  prepared  opening  and 

mark the positions of the fixing holes. 

Take  care  not  to  crush  or  introduce  undesirable 
bends/kinks in the ducting when pushing the extractor into 
place. 

ELECTRICAL HAZARD 

DISCONNECT ELECTRICAL SUPPLY 

BEFORE PROCEEDING FURTHER 

 