STEP 6
Non-Electric AGA’s only - Fit 2 layers of insulation blanket JPAD210722 (supplied
with hob) on top of the oven roof.
STEP 7
Feed cable through the grommets.
Continue to feed cable as the hob is placed in position.
Secure top plate.
Connect the cable to a fused double pole switch or fit the 3 pin plug (supplied) which
can then be fitted to an unswitched socket, as described in General Requirements.
Fuse Rating - 13 Amps
Cable Colour Coding
Brown - Live
Blue - Neutral
Green/Yellow - Earth
DESN 511733