4
Technical data
HOTPLATE - Natural Gas
NATURAL GAS
Right-hand Front
Left-hand Rear
Right-hand Rear
Left-hand Front
BURNER TYPE
ULTRA - RAPID (WOK)
RAPID
SEMI - RAPID
SEMI - RAPID
MAXIMUM HEAT INPUT
3.5 KW
12,000 Btu/hr
3.1 KW
10,600 Btu/hr
1.8 KW
6,150 Btu/hr
1.8 KW
6,150 Btu/hr
INJECTOR MARKING
170
155
118
120
PRESSURE POINT POSITION :
Front left hand hotplate injector
PRESSURE SETTING :
4” wg
BURNER IGNITION :
H.T. Spark
HOTPLATE - Propane
Right-hand Front
Left-hand Rear
Right-hand Rear
Left-hand Front
BURNER TYPE
ULTRA - RAPID (WOK)
RAPID
SEMI - RAPID
SEMI - RAPID
MAXIMUM HEAT INPUT
12,000 Btu/hr
3.5 KW
(250 g/h)
(0.5 l/h)
10,600 Btu/hr
3.1 KW
(221 g/h)
(0.43 l/h)
6,150 Btu/hr
1.8 KW
(128 g/h)
(0.26 l/h)
6,150 Btu/hr
1.8 KW
(128 g/h)
(0.26 l/h)
INJECTOR MARKING
105
94
72
75
PRESSURE POINT POSITION :
Front left hand hotplate injector
PRESSURE SETTING :
10” wg
BURNER IGNITION :
H.T. Spark
ELECTRIC GRILL & OVENS :
240 VOLT 60 Hz SINGLE PHASE 30 AMP
GRILL ELEMENT POWER RATING:
2 x 1.05 kW
TOP OVEN POWER RATING :
1.0 KW
LOWER OVEN (FANNED CONVECTION) :
1.5 kW
Typical section view of burner flames
7/16”
(11mm)
11/16”
(17.5mm)
9/16”
(14mm)
15/16”
(24mm)
1/2”
(12.5mm)
7/8”
(22mm)
L.H.F. Hotplate Burner
R.H.R. Hotplate Burner
L.H.R. and R.H.F. Hotplate Burner