9
Injectors
Remove the burner caps and flame spreaders. Remove the old jets. Fit the new jets (see ‘Technical Data’ section for the correct
jets). Reassemble in the reverse order (see
Fig. 1.13
,
Fig. 1.14
and
Fig. 1.15
).
Bypass Screw Adjustment
Pull off all the control knobs and bezels. Turn the bypass screw on each control clockwise to the stop (see
Fig. 1.16
).
Gas Regulator
The gas regulator which is located at the rear, left-hand side of the cooker, below the top plate, is pre-set for Natural Gas.
Remove the cap from the regulator, pull the plastic insert from the cap, turn the insert round and re-locate into the cap as
shown (see
Fig. 1.17
and
Fig. 1.18
).
Replace the cap.
Stick on Label
Stick the LP gas label over the natural gas part of the appliance data label.
Pressure Testing
Connect the appliance to the gas supply.
The pressure test point is on the front, left-hand hotplate injector.
Place the wok burner head, burner cap and ring into position on the hotplate. Light the burner by pushing in the appropriate
control knob and turning it anti clockwise to the
FULL ON
position (large flame symbol).
For
Natural Gas
appliances, the manifold pressure should be 4 inches water gauge (1kpa).
For
LPG
appliances, the manifold pressure should be 10 inches water gauge (2.54kpa).
Turn off the tap, disconnect the pressure gauge and refit test point blanking screw.
Check operation of all the burners.
Check for gas tightness.
WARNING SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON.
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Check the ‘Technical Data’ section, that the hob is convertible to the gas you want to use.
A suitably competent person must perform the conversion. After conversion the installation must comply with the relevant
regulations and also the local electricity supply company requirements. Read the instructions before converting this
appliance.
n
n
Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead to
prosecution.
n
n
When servicing or replacing gas carrying components disconnect from the gas supply before starting operation.
Check the appliance is gas sound after completion.
n
n
DO NOT use reconditioned or unauthorised gas controls.
n
n
Disconnect from the electricity and gas supply before servicing.
n
n
Before electrical reconnection, check that the appliance is electrically safe.
AGA Module Gas Hob (AUS)