AGA marvel 4EAF Installation, Operation And Maintenance Instructions Download Page 4

These refrigerators and freezers have been engineered for in

-

stitutional and industrial hazardous locations and meet Under

-

writers Laboratories specifications for Class 1 Groups C and D. 

Approved by the New York City Board of Standards and Appeals 

under Calendar Number 496-80-SA.

Select Location

The proper location will ensure peak performance of your ap

-

pliance. Choose a location where the unit will be out of direct 

sunlight and away from heat sources.

The condenser is mounted on the back of the cabinet so the unit 

cannot be built in. At least 1-1/2 inches (3.8cm) of clearance 

from the back wall is required for proper ventilation.

Installation

The 4.5 and 6.1 cu. ft. refrigerators are designed for recessed as 

well as freestanding installation.

To recess the 4.5 and 6.1 cu. ft. models make the opening 

25-7/8” (657.4mm) wide x 35-3/4” (908.1mm) high x 27-1/2” 

(698.5mm) deep with ample provision for wiring as described 

in the following paragraph “Sealing” instructions. Other service 

information can be found on pages 7 and 8. Provisions should be 

made to easily remove the unit for servicing.

Do not back the unit up to heat ducts or hot water lines.

Cabinet Clearance

Ventilation is required from the bottom front section of the unit. 

Keep this area open and clear of any obstructions.     

Leveling Legs

Adjustable legs at the front and rear corners of the unit should 

be set so the unit is firmly positioned on the floor and level from 

side to side and front to back. Turn leveling legs clockwise to 

raise unit, counterclockwise to lower it. (See Figure 1).

Electrical Connection

Check serial plate for correct power supply. Use only electrical 

power supply as specified on your appliance serial plate.

Wiring

Hazardous location models are not supplied with power cords or 

plugs. All wiring methods must comply with the latest National 

Electrical Code, Article 501-4 for Class 1, Divisions 1 and 2.

Leveling Legs

Front Grille, keep 

this

area open.

Figure 1

Front Grille

Do not obstruct the front grille. The openings within the front 

grille provides air to flow into and exit from the refrigerator 

condenser. For this reason it is important this area to not be ob

-

structed and be kept clean. AGA MARVEL does not recommend 

the use of custom made grilles as air flow may be restricted 

because of inadequate openings. (See Figure 1).

Sealing 

Article 501-5 of the National Electrical Code Class 1, Division 1 

requires that in Class 1 Division 1 locations, seals shall be located 

as follows:

In each conduit run entering an enclosure for switches , circuit 

breakers, fuses, relays, resistors, or other apparatus which may 

produce arcs, sparks, or high temperatures, seals shall be placed 

as close as practicable and in no case more than 18” (45.7cm) for 

such enclosures. 

INSTALLING YOUR REFRIGERATOR

3

Temperature

Control access

Summary of Contents for 4EAF

Page 1: ...Installation Operation and Maintenance Instructions Hazardous Location Models 4EAF Freezer 6EAR Refrigerator 6ERF Combination Refrigerator Freezer...

Page 2: ...Removing the packaging Warranty registration Installing your refrigerator Select location Installation Cabinet clearances Leveling legs Electrical Connection Wiring Sealing Handle installation Door al...

Page 3: ...ERCHANDISE TO THE MANUFAC TURER FILE THE CLAIM WITH THE RETAILER Help Prevent Tragedies Child entrapment and suffocation are not problems of the past Junked or abandoned refrigerators are still danger...

Page 4: ...Adjustable legs at the front and rear corners of the unit should be set so the unit is firmly positioned on the floor and level from side to side and front to back Turn leveling legs clockwise to rais...

Page 5: ...the door may be adjusted by loosening the 2 screws which secure the hinge adapter brackets to the door and adjusting the door side to side Use a 5 32 hex key wrench for this procedure See Figure 3 bel...

Page 6: ...A minimum depth of 27 1 2 69 9cm is required with ample provision for wiring DIMENSIONS FOR 4EAF 6EAR 6ERF WITH SOLID DOOR ROUGH IN OPENING FOR 4EAF 6EAR 6ERF WITH SOLID DOOR 23 7 8 60 7CM 22 55 9cm...

Page 7: ...hot appliance cooker dishwasher etc heating air duct or other heat sources 2 Install product out of direct sunlight 3 Assure the toe grille vents at front of unit beneath door are not obstructed and...

Page 8: ...er for efficient performance Use care when cleaning the condenser The condenser fins are sharp and could cause cuts Cabinet The painted cabinet can be washed with mild soap and water and thoroughly ri...

Page 9: ...bration Unit not level Level unit see Leveling Legs on page 3 Unit will not run No power to unit Circuit breaker tripped reset circuit breaker Before You Call for Service If the unit appears to be mal...

Page 10: ...uct is outside the first year warranty period AGA MARVEL Customer Service can provide recommendations of service centers in your area A listing of authorized service centers is also available at www a...

Page 11: ...oduct is not defective the component shall be reshipped to the buyer at the buyer s expense No component will be returned to AGA MARVEL without its prior consent The above warranties do not cover Ship...

Page 12: ...tice Such revisions do not entitle the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www agamarvel com P O Box 400 1260 E VanDein...