A G S P R A Y . C O M 1 2
FIG. 20B
FIG. 20A
GREASING
- Wipe grease fitting with a clean cloth before greasing
to prevent injecting dirt and frit into joint.
- Replace and repair broken fittings immediately.
- If a fitting will not take grease, remove and clean
thoroughly. Also clean lubricant passageway.
Replace fitting if necessary.
*Note: Grease 19 points 8 hours or daily.
L/R GREASE LOCATIONS
1. L/R Breakaway Hinge
2. L/R Outer Boom Hinge
3. L/R Inner Boom Hinge
4. L/R Center Section Bushing (Lower)
5. L/R Center Section Bushing (Upper)
6. Parallel Hinge Bushings (Total of 8)
(4 Top Pins & 4 Bottom Pins)
7. Center Pivot Pin
Apply adequate grease to the following:
3
7
4
5
2
1
3 4
5
2
1
6
6