![AG SHIELD 405824 Operator’S Handbook And Parts Manual Download Page 20](http://html.mh-extra.com/html/ag-shield/405824/405824_operators-handbook-and-parts-manual_2865540020.webp)
20
Figure 10 Install the joiner link into
chain
coupler with one side bent out of way
.
1. Install hydraulic hoses as follows:
2. install the adapter and hoses on to the new Ag Shield motor as shown in parts page 26--
section Right Hand end MOUNT CASE 1042 36 foot.
3. The rear hose of the motor, part #118816 will connect to fitting "G" below- the tank return
line of the draper motor becomes the pressure line of the Ag shield auger motor. .
4. The forward hose on the Ag Shield motor- part # 118825 will connect to hose "H" below.
5. Test direction of rotation to be down on the front of the auger. for operation in field, set
speed of the canvases, and use the flow control supplied to set the auger flighting speed to
be 5% or slightly greater than the canvases. see operations below. Below is not a photo of
a 1042 Case - but the principal applies, Determine the correct rotation of the motor as
follows. The oil will enter the pressure port of the motor and go the long way around the
motor to arrive the tank line
Summary of Contents for 405824
Page 2: ......
Page 4: ......
Page 22: ...22 4 2 MOTOR INSTALLATION Notch tin in side of header for motor to fit in ...
Page 30: ......