background image

© Copyright LOTRONIC 2016                                      DC54DMX 

Page 2 

 
 
Thank you for having chosen our 

AFX LIGHT 54CH MINI DMX CONTROLLER

. For your own safety, please read this user manual 

carefully before installing the device. 

SAFETY INTRODUCTION 

 

If the device has been exposed to temperature changes due to environmental changes, do not switch it on immediately. 

The arising condensation could damage the device. Leave the device switched off until it has reached room temperature. 

 

It is essential that the device is earthed. A qualified person must carry out the electric connection. 

 

Make sure that the available voltage is not higher than stated at the end of this manual. 

 

Make sure the power cord is never crimped or damaged. If it is damaged, ask your dealer or authorized agent to replace 

the power cord. 

 

Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power cord by plug. 

Never pull out the plug by tugging the power cord. 

 

DISCONNECT DEVICE: Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect 

device shall remain readily operable. 

 

Shields, lenses or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their 

effectiveness is impaired, for example by cracks or deep scratches. 

CAUTION: 

1. Be very careful during installation. Since you will be working with a dangerous voltage you can suffer a life-threatening 
electric shock when touching live wired. 
2. Never look directly into the light source, as sensitive persons may suffer an epileptic shock. 
3. Please be aware that damages caused by manual modifications to the device are not subject to warranty. Keep away from 
children and non-professionals. 
4. The light doesn’t include any spare parts for repair, please check if all the parts are well installed and screws are fitted 
tightly before operating. Do not use the light when the cover is open. 

 
GENERAL GUIDELINES 

 

This device is only allowed to be operated with an alternating current of max. 110-240VAC and was designed for indoor 

use only. 

 

Do not shake the device. Avoid brute force when installing or operating it. 

 

When choosing the installation spot, please make sure that the device is not exposed to extreme heat, moisture or dust. 

The minimum distance between light-output from the projector and the illuminated surface must be more than 1 meter. 
Keep a distance to any flammable objects of at least 5m. 

 

Operate the device only after having familiarized yourself with its functions. Do not permit operation by person not 

qualified for operating the device. Most damages are the result of unprofessional operation. 

 

Please use the original packaging if the device is to be transported. 

 

For safety reasons, please be aware that all modifications on the device are forbidden. Furthermore, any other operation 

may lead to short-circuit, burns, electric shock, lamp explosion, crash, etc. If this device will be operated in any way 
different to the one described in this manual, the product may suffer damages and the guarantee becomes void. 

 
Power Supply and Signal Cable Connection 

1. Mains Power connection 
The exclusive plug should be used between the connection of unit and power. Please ensure that the rated voltage and 
frequency are accordance with the power supply. The required input voltage and frequency are: 110-240VAC 
 
 
 

GB 

Summary of Contents for DC-54DMX

Page 1: ...1 M MI IN NI I D DM MX X C CO ON NT TR RO OL LL LE ER R M MI IN NI I C CO ON NT TR RO OL LL LE EU UR R D DM MX X D DM MX X S ST TE EU UE ER RP PU UL LT T DC 54DMX 15 1843 GB INSTRUCTION MANUAL F MANUE...

Page 2: ...be aware that damages caused by manual modifications to the device are not subject to warranty Keep away from children and non professionals 4 The light doesn t include any spare parts for repair plea...

Page 3: ...logously till connected all the slave lights and insert the last connector to the output of the final light Notice the diameter of core of every cable should be 0 5mm at least double core shelter cabl...

Page 4: ...zero When self test is complete you will get the following screen According to the type of effect of light connected to the DMX controller you can synchronize a projector to another For example you ha...

Page 5: ...54 controllable channels You can then use the sliders to control the DMX512 line that was connected to the device Here is the table showing the Number of channels according to the page 1 1 a 2 7 a 12...

Page 6: ...ction and select a scene you want to replace with the buttons UP and Down Then press INSERT button again to add this new scene Delete the old selected one by pressing the button of DELETE twice Press...

Page 7: ...the device have to be tightly connected and must not be corroded There must not be any deformations on the housing The electric power supply cables must not show any damage material fatigue or sedime...

Page 8: ...arder directement dans la source de lumi re Elle peut provoquer une crise d pilepsie chez des personnes sensibles 3 Les dommages r sultant du non respect des instructions ou de la modification de l ap...

Page 9: ...nce de fin de ligne consiste en une fiche XLR qui comporte une r sistance de 120 entre les broches 2 et 3 I N O U T I N O U T O U T I N 1 2 3 D M X IN D M X O U T Note Utilisez du c ble double blindag...

Page 10: ...les fonctions z ro Quand l initialisation est termin e vous obtenez l affichage ci dessous Selon le type d effet lumi re connect au contr leur DMX vous pouvez synchroniser un projecteur avec un autre...

Page 11: ...37 a 42 8 43 a 48 9 49 a 54 3 programmer une sc ne Pour entrer en mode programmation appuyer sur le bouton A pendant 3 secondes L afficheur PROG indique le num ro du programme en clignotant rapidemen...

Page 12: ...e bouton A Apr s s lectionner le programme supprimer l aide des boutons UP et DOWN Appuyer sur le bouton DELETE le message AL clignote sur l afficheur SCENES Appuyer de nouveau sur le bouton DELETE po...

Page 13: ...ant d effectuer le nettoyage ou la maintenance Ne pas utiliser d alcool ou de solvants chimiques pour nettoyer l appareil Si l appareil ne fonctionne pas v rifiez si le fusible a saut Si c est le cas...

Page 14: ...eanspruch Von Kindern und Laien fernhalten 4 Das Ger t enth lt keine vom Bediener auswechselbaren Teile Das Ger t nicht bei offenem Geh use betreiben ALLGEMEINE BETRIEBSREGELN Dieses Ger t darf nur vo...

Page 15: ...s mindestens 0 5mm betragen BESCHREIBUNG 1 Bedienfeld INSERT DELETE AB UP DOWN SELECT 2 Schieberegler 1 2 3 4 5 6 3 Anzeige der Szenen SCENES 4 Programmanzeige PROG 5 Projektoranzeige PROJ 6 DMX Einga...

Page 16: ...t sind und einen Scaneffekt erzeugen ist der bergang aktiv Schieberegler 2 Um die interne Synchronisation der Strahler zu aktivieren halten Sie die Taste SELECT 2 Sekunden lang gedr ckt Die Nummer des...

Page 17: ...n bis zu 9 Programme 1 bis 9 speichern und jedes Programm kann 50 Szenen 1 bis 50 enthalten Das Display SCENES zeigt die letzte Szene an 00 wenn keine Szene in diesem Programm gespeichert ist Wenn Sie...

Page 18: ...mmierbetrieb zu verlassen 5 Abspielen eines Programms A Taste dr cken und dann mit den UP DOWN Tasten das gew nschte Programm w hlen Das Programm wird automatisch und der Reihenfolge nach von der erst...

Page 19: ...NG Das Ger t vor Wartungsarbeiten vom Netz trennen Wenn das Ger t nicht funktioniert pr fen Sie die Sicherung Ersetzen Sie eine defekte Sicherung nur durch eine Neue die genau dieselben technischen Ei...

Reviews: