© Copyright LOTRONIC 2018 FOG1500W-T
Page 4
The connection between the output of master unit and the input of slave unit must be carried out by the 3-pin XLR
cable which is provided by the manufacturer. Connect the signal cable from the DMX output of the controller to the
input of the first master unit, then connect the DMX input of slave unit from the DMX output of the master unit, etc,
until you have connected all slaves. Insert the last connector to the input of the final light. (Note: the core diameter of
every cable should be 0.5mm at least, double core screened cable should be used).The signal connection must be
done via the supplied 3-pin XLR cable. Note: Make sure that the internal wires of the 3 pins XLR cable don’t touch
each other or the connector.
A DMX signal terminator is recommended on the output of the last unit of the chain. A DMX terminator is a XLR
connector with a 120Ω resistor between pin 2 and pin 3 of the XLR connector
DESCRIPTION
1) INTERVAL AND DURATION TIME CONTROL
These controls are used to adjust interval time and duration when you use the fog
machine in timer mode.
2) SMOKE OUTPUT CONTROL
This control is used to set the volume of fog when you use fog machine in CONT
mode
3) TIMER BUTTON
This button is used to select the timer mode. In this mode, fog machine run in
stand-alone mode. It sprays the fog with the value (interval and output time) you set
with interval and output time control buttons. When you push this button, the timer led
lights on. Push a second time this button to disable timer function
4) CONT BUTTON
This button is used to select CONT mode. In this mode, the fog machine sprays fog in continuous mode. The
volume of fog is set with the smoke output control (2). When you push this button, CONT led lights on. Push
another time this button to disable this function
5)
MANUAL BUTTON
This button is used to select manual mode. Press this button to sprays 100% of volume all the time you hold the
button. When you release the button, the spray of fog stops.
OPERATION
1. Control panel operation
When you switch the power button to on, the fog machine will heat during 10 minutes. When the fog machine is
ready to spray, the green led of the wired remote control will light. So you can select one of the three operating
modes : Timer, Continuous or Manual ( see remote control description )
2. DMX Channel Table
To set DMX channel use, use the DIP switches. Check the following table to choose the good DMX address :
ADDRESS
SWITCH DIP
9 8 7 6 5 4 3 2 1
01
0 0 0 0 0 0 0 0 1
02
0 0 0 0 0 0 0 1 0
03
0 0 0 0 0 0 0 1 1
1= On
0 = Off