Instruction manual 

Buffer tank ABT 50 

1

 

Explanations to the installation and operation manual 

Installation and operation manual i san important parto of the scope 
of delivery. That is why we recommend: 

 

Read the installation and operating instruction before installing 
the device. 

 

Keep the installation and operating instruction for the entire life 
of the device. 

 

Hand over the installation and operating instructions to any sub-
sequent owner or user of the device. 

1.1

 

Safety messeges and hazard categories 

 

DANGER 

 

 

Specifies the type and source of a threat 

 

Describes what to do to avoid a hazard. 

 

Threats have 3 levels: 

Danger 

Importance 

DANGER 

DANGER indicates a hazardous situation, which, 

if not avoided, will result in death or serious injury. 

WARNING 

WARNING indicates a potentially hazardous situa-
tion, which, if not avoided, can result in serious 
injury or equipment damage. 

NOTICE 

NOTICE  indicates  a  hazardous  situation,  which,  if 
not avoided, can result in equipment damage. 

 

 

2

 

Information on safety 

2.1

 

Intended use of the device 

The  ABT  50  buffer  tank  is  intended  for  use  in  a  closed  heating  or 
cooling  system  in  accordance  with  EN  12828.  The  ABT  50  buffer 
tank  is  designed  for  combining  various  heat/cooling  sources  with  a 
heating/cooling system. It enables the combination of one or two so-
urces plus an electric heater.  
In the installation with heat pump, buffer guarantees an adequate flu-
id  flow  through  the  heat  exchanger.  With  air  source  heat  pumps,  it 
also ensures that there is sufficient capacity for defrosting the exten-
ral unit when required. Any use other than that indicated in point. 2.1 
is forbidden. 

Summary of Contents for 68 050 00

Page 1: ...information regatding safety Keep the instruction manual 953 001 0160 AFRISO sp z o o Szałsza ul Kościelna 7 42 677 Czekanów Phone 48 32 330 33 55 Fax 48 32 330 33 51 zok afriso pl www afriso pl Installation and operation manual Buffer tank ABT 50 Art No 68 050 00 ...

Page 2: ...ct 4 2 5 Using additional parts and accessories 4 2 6 Liability 4 3 Product description 5 3 1 Buffer construction 6 3 2 Dimensions 7 3 3 Buffer operation 9 3 4 Scope of delivery 9 4 Transport and storage 9 5 Examples of application schemes 10 6 Technical data 12 7 Approvals 12 8 Installation and commissioning 13 9 Selection and instalation of electric element 15 10 Maintenance 17 11 Decommissionin...

Page 3: ...ill result in death or serious injury WARNING WARNING indicates a potentially hazardous situa tion which if not avoided can result in serious injury or equipment damage NOTICE NOTICE indicates a hazardous situation which if not avoided can result in equipment damage 2 Information on safety 2 1 Intended use of the device The ABT 50 buffer tank is intended for use in a closed heating or cooling syst...

Page 4: ...e hazards and are prohibited for safety reasons 2 5 Using additional parts and accessories Improper additional parts and accessories may damage the device Use only original spare parts and accessories from the manufacturer 2 6 Liability The manufacturer is not responsible for direct damages or their consequences resulting from inaccurate reading of assembly and usage instructions and recommendatio...

Page 5: ...esponsible for the desired stratified temperature distribution inside the buffer and at the same time enables the mixing of supply and return streams Dedicated wall mounting brackets are included in the scope of delivery to the buffer tank which enable smooth mounting of the buffer storage on a wall The ABT 50 storage tank is designed for direct connection to the AFRISO KSV boilers manifolds up to...

Page 6: ... of buffer tank ABT 50 Heat source connections G1 F Connection G F Connection G F Buffer front Buffer right and left side Partial baffle Pipe entering the zone above baffle Installation connections G1 Buffer bottom Buffer top Heating element connection G1 F Pipe entering the zone under the baffle ...

Page 7: ...Instruction manual Buffer tank ABT 50 7 3 2 Dimensions Figure 2 Dimensions of buffer tank ABT 50 without insulation ...

Page 8: ...Instruction manual 8 Buffer tank ABT 50 Figure 3 Dimension of buffer tank ABT 50 with insulation ...

Page 9: ...ect for the correct operation of the heat pump 3 4 Scope of delivery The scope of the delivery of the ABT 50 buffer tank includes buffer tank ABT 50 2 half union G1 F x union nut G1 plug G1 for closing heating element connection 2 plugs G1 for closing second heat cold source connections plug G automatic air vent with mounting valve R wall mounting brackets installation and operation manual 4 Trans...

Page 10: ...ual 10 Buffer tank ABT 50 5 Examples of application schemes F i Figure 4 Buffer tank ABT 50 used in installation with radiator and sur face heating to connect two heat source gas boiler and fireplace with water jacket ...

Page 11: ...manual Buffer tank ABT 50 11 Figure 5 Buffer tank ABT 50 used in surface heating installation with monoblock type heat pump Figure 6 Buffer tank ABT 50 used in surface heating instalation with split type heat pump ...

Page 12: ...er manifold connections 2 x G1 spacing 125 mm 2 x half union G1 F x union nut G1 in packa ge Heating element connection G1 F Energy class In accordance with EU Regulation 812 2013 C Standstill loss In accordance with EU Regulation 814 2013 56 4 W Storage capacity In accordance with EU Regulation 814 2013 52 0 l 7 Approvals Buffer tank ABT 50 subject to the Pressure Directive 2014 68 EU and in acco...

Page 13: ...ackets For connection of the he at cooling source use the side connections G1 F on the left or right side of the buffer Unused connections must be plugged with the plugs which are provided in the delivery An automatic air vent with mounting valve must be screwed into the upper G F connection and a plug into the lower G F connection The plug can be repla ced by a drain valve Art No 42 407 or a temp...

Page 14: ...Buffer tank ABT 50 Depending on the orientation of the buffer the supply and return connections from the system may be interchanged see Fig 8 for examples Figure 8 Flows inside the buffer tank depending on connection manner ...

Page 15: ...with greater capacity WARNING Risk of burns Burns can occur from the hot medium during installation and maintenace work Ensure that the installation has cooled down sufficiently before proceeding 9 Selection and instalation of electric element Depending on the orientation of the ABT 50 buffer tank the electric element can be screwed into a dedicated G1 F connection or into one of the connections G...

Page 16: ...onection WARNING Mains voltage 230 V AC can cause serious injury or death Do not allow the element cover to come into contact with liquid Disconnect the element from the mains before servicing Do not make any changes to the device Follow the guides which are included in element instruction manual ...

Page 17: ...t this product must not be disposed together with normal household waste Dispose of the product in accordance with the local directives and guidlines Buffer tank ABT 50 consist of materials that can be recycled 12 Warranty Product warranty in accordance with the general conditions of sale and delivery 13 Copyright Copyright to the manual belong to AFRISO sp z o o Reprinting translation and reprodu...

Reviews: