AFi RR-985D-SL Instruction Manual Download Page 6

 

6

DATA INPUT / OUTPUT CONNECTIONS 

Data input and output connections are made via terminal blocks on the back of the RR-482D-
1470/1490 unit. See the drawings below for proper orientation of input and output connections. 
Please note that the far right pin on each connection drawing corresponds with the far right pin 
when looking at the terminal block from the back of the unit. 
 
 

 

 
 
TYPICAL SYSTEM DATA CONNECTIONS 

The RS422 or RS485 four wire interconnection between the RR-985D-SL and the copper 
device to which it is attached is based on industry standard EIA terminology for the transmission 
of electronic data signals. Using this terminology, the driver of an electronic signal is labeled TX 
or Data Out. Correspondingly, the receiver of an electronic signal is labeled RX or Data In. 
Following this standard, the Data Out of the copper device is connected to the Data In of the 
RR-985D-SL. The plus terminal of the copper device is connected to the plus terminal of the 
RR-985D-SL and the minus is connected to the minus. The reverse flow of data from the RR-
985D-SL to the copper device follows the same pattern. Not all manufactures follow standard 
EIA terminology. Consult the installation instructions for your copper device if you are unsure 
which two wires are the drive (data out) wires and which two wires are the receive (data in) 
wires. 
 

 

Please note that Data In on the RR-985D-SL becomes Data Out on the RT-985D-SL after going 
across the fiber. The reverse flow follows the same orientation. 

Summary of Contents for RR-985D-SL

Page 1: ...Copyright 2007 American Fibertek Inc 0531JD Instruction Manual RR 985D SL Eight Channel Video Receiver With Two Channels of Multi Protocol Data And Remote Diagnostic Interface...

Page 2: ...ower Connection 4 Fiber Connections 5 Video Input Connections 5 Data Input Output Connections 6 Data Configuration Switches 7 Data Termination And Bias Switches 7 RR 980D 1510 Status LED Indicators 9...

Page 3: ...get range of 0 to 15dB Refer to the data sheets for detailed performance specifications The individual components that make up the RR 985D SL series unit are combined in a rack mount configuration tha...

Page 4: ...configuration is shown below Use a small screwdriver to push and lock the turn fasteners into place POWER SOURCE Power to the unit is supplied by the subrack Please refer to the SR 20D and PSR 2 instr...

Page 5: ...is made via a SC connector located on the bottom of the RR CWDM 4 Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used See the drawing below for the RR 985D S...

Page 6: ...driver of an electronic signal is labeled TX or Data Out Correspondingly the receiver of an electronic signal is labeled RX or Data In Following this standard the Data Out of the copper device is conn...

Page 7: ...r changes to the default switch settings Switches are available internally on the RR 482D 1470 1490 that allow offset bias and termination features to be activated when using RS485 data These switches...

Page 8: ...r high impedance state very rapidly On even short lengths of wire there can exist a residual voltage after a driver circuit turns off This can interfere with circuits that are used to detect the Hi Z...

Page 9: ...cator monitors the optical input power of the data signal that is being received at the RR 980D 1510 from the RT 980D 1510 DC power and optical input status associated with this LED are summarized bel...

Page 10: ...provides the following front panel LED status indicators to aid in installation and troubleshooting DATA TX RX INDICATORS DATA TX and DATA RX indicators are provided to monitor each of the two availab...

Page 11: ...R 482D 1470 1490 and out onto the electrical interface The intensity of this indicator will vary with input data patterns however in typical applications it will cycle on and off as data is received D...

Page 12: ...THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In a...