AFi RR-985D-SL Instruction Manual Download Page 3

 

3

INSTALLATION AND OPERATION INSTRUCTIONS 

 

INTRODUCTION 

 

Thank you for purchasing your American Fibertek Series 985D-SL singlemode eight channel 
video multiplexer with two channels of multi-protocol data and remote diagnostic interface. 
Please take a few minutes to read these installation instructions in order to obtain the maximum 
performance from this product. 
 

FUNCTIONAL DESCRIPTION 

The RR-985D-SL operates as half of a receiver / receiver pair for the transmission of eight 
channels of high performance 10 bit digital NTSC, PAL, RS170, or RS343 video signals. The 
RR-985D-SL also supports combinations of up to two bi-directional RS422, RS232, or RS485 
data channels or two Manchester data channels. The RR-985D-SL is designed to operate with 
the RT-985D-SL video transmitter with bi-directional data over one singlemode fiber optic cable. 
 

 

The RR-985D-SL detects and demultiplexes an optical serial data stream containing eight video 
signals along with two data signals at 1310 nm wavelength. The RR-985D-SL also multiplexes 
two data input signals into a high speed serial data stream. This serial data stream modulates a 
laser at 1550 nm wavelength. The 985D-SL Series product is designed to operate on 9 um 
singlemode fiber over an optical loss budget range of 0 to 15dB. Refer to the data sheets for 
detailed performance specifications. 
 
The individual components that make up the RR-985D-SL series unit are combined in a rack 
mount configuration that is inserted into the SR-20D subrack. The RR-985D-SL consists of a 
RR-980D-1510, a RR-CWDM-4, and a RR-482D-1470/1490. The RR-980D-1510 unit 
demultiplexes one distinct singlemode wavelength of 1510 nm  into eight video outputs. The RT-
482D-1470/1490 transmits and receives up to two bi-directional RS422, RS232, or RS485 data 
channels or transmits two Manchester data channels using the 1470 nm and 1490 nm 
wavelengths. The RR-CWDM-4 unit optically demultiplexes these distinct wavelengths from one 
singlemode fiber.  
 
The RS485 data channel may be configured for 2-wire (half duplex) or 4-wire (full duplex) 
operation with or without biasing. Switch selectable internal 120 ohm terminations are available 
for RS422 or RS485 data. 
 
This unit is designed for rack mounting in the American Fibertek SR-20D/2 subrack. Slide in 
rack mounting, detachable terminal blocks, and LED indicators provide for easy installation and 
monitoring of video, data, and optical power.  
 
The RR-985D-SL has a built in capability to be remotely monitored through the Afinety Remote 
Diagnostics System. A SR-20D/2 subrack and a RD-20D diagnostic card are required to 
facilitate this feature. Please refer to the SR-20D/2 and RD-20D Instruction Manuals for proper 
operation of this feature. 

Summary of Contents for RR-985D-SL

Page 1: ...Copyright 2007 American Fibertek Inc 0531JD Instruction Manual RR 985D SL Eight Channel Video Receiver With Two Channels of Multi Protocol Data And Remote Diagnostic Interface...

Page 2: ...ower Connection 4 Fiber Connections 5 Video Input Connections 5 Data Input Output Connections 6 Data Configuration Switches 7 Data Termination And Bias Switches 7 RR 980D 1510 Status LED Indicators 9...

Page 3: ...get range of 0 to 15dB Refer to the data sheets for detailed performance specifications The individual components that make up the RR 985D SL series unit are combined in a rack mount configuration tha...

Page 4: ...configuration is shown below Use a small screwdriver to push and lock the turn fasteners into place POWER SOURCE Power to the unit is supplied by the subrack Please refer to the SR 20D and PSR 2 instr...

Page 5: ...is made via a SC connector located on the bottom of the RR CWDM 4 Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used See the drawing below for the RR 985D S...

Page 6: ...driver of an electronic signal is labeled TX or Data Out Correspondingly the receiver of an electronic signal is labeled RX or Data In Following this standard the Data Out of the copper device is conn...

Page 7: ...r changes to the default switch settings Switches are available internally on the RR 482D 1470 1490 that allow offset bias and termination features to be activated when using RS485 data These switches...

Page 8: ...r high impedance state very rapidly On even short lengths of wire there can exist a residual voltage after a driver circuit turns off This can interfere with circuits that are used to detect the Hi Z...

Page 9: ...cator monitors the optical input power of the data signal that is being received at the RR 980D 1510 from the RT 980D 1510 DC power and optical input status associated with this LED are summarized bel...

Page 10: ...provides the following front panel LED status indicators to aid in installation and troubleshooting DATA TX RX INDICATORS DATA TX and DATA RX indicators are provided to monitor each of the two availab...

Page 11: ...R 482D 1470 1490 and out onto the electrical interface The intensity of this indicator will vary with input data patterns however in typical applications it will cycle on and off as data is received D...

Page 12: ...THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In a...

Reviews: