AFi MR-913D Instruction Manual Download Page 3

 

3

INSTALLATION AND OPERATION INSTRUCTIONS 

 

INTRODUCTION 

Thank you for purchasing your American Fibertek MR-913D multimode video receiver with bi-
directional multi-protocol data and remote diagnostic interface. Please take a few minutes to read these 
installation instructions in order to obtain the maximum performance from this product. 
 

FUNCTIONAL DESCRIPTION 

The MR-913D operates as half of a transmitter / receiver pair for the transmission of high performance 
10 bit digital NTSC, PAL, RS170, or RS343 video signals. The MR-913D also supports up to three bi-
directional channels of RS485 (2 or 4 wire), RS422, RS232 or Manchester data. Switch selection 
allows for multiple data configurations in one of the following three formats: 
  

Channel 1: RS422 or RS232 data 
Channel 2: RS422 or RS232 data 
Channel 3: RS422 or RS232 data 

Or: 
 

Channel 1: RS422 or RS232 data 
Channel 2: RS485 (2 or 4 wire) or Manchester data  
Channel 3: RS422 or RS232 data 

Or: 
 

Channel 1: RS485 (2 or 4 wire) or Manchester data 
Channel 2: RS485 (2 or 4 wire) or Manchester data 
Channel 3: Not available in this configuration 

 

NOTE: This unit is shipped in the following default configuration. For other configurations, 
please refer to the DATA CONFIGURATION section for changes to the default switch settings.  
 

Channel 1: RS422 data 
Channel 2: RS485 (4 wire) or Manchester data  
Channel 3: RS232 data  

 
The MR-913D is designed to operate with the MT-913D or RT-913D video transmitter with bi-directional 
data over one multimode fiber optic cable. 
 
The MR-913D multiplexes up to three data signals into a high speed serial data stream. This serial data 
stream modulates a laser at 1550 nm wavelength. The MR-913D also detects and demultiplexes a 
return optical serial data stream signal containing a single video input signal along with up to three data 
channels at 1310 nm wavelength. The 913D Series product is designed to operate over an optical loss 
budget range of 0 to 12 dB. Refer to the data sheets for detailed performance specifications. 
 
The RS485 channel may be configured for 2-wire (half duplex) or 4-wire (full duplex) operation with or 
without biasing. Switch selectable internal 120 ohm terminations are available for RS422 or RS485 
data. 
 
This unit is contained in a rugged aluminum housing with internal dc voltage regulation. The detachable 
terminal blocks and LED indicators provide for easy installation and monitoring of video, data, and 
optical power.  
 
The MR-913D is designed for mounting as a modular stand alone unit. For a rack mounted version 
please see the RR-913D. 
 
The MR-913D has a built in capability to be remotely monitored through the Afinety Remote 
Diagnostics System. A SR-20D/2 subrack and a RD-20D diagnostic card are required to facilitate this 
feature. Please refer to the SR-20D/2 and RD-20D Instruction Manuals for proper operation of this 
feature. 

Summary of Contents for MR-913D

Page 1: ...Copyright 2005 American Fibertek Inc 0824JD Instruction Manual MR 913D Video Receiver With Bi directional Multi Protocol Data And Remote Diagnostic Interface...

Page 2: ...Source 4 Power Connection 4 Fiber Connection 4 Video Input Connection 4 Data Input Output Connections 5 Typical System Data Connections 5 Data Configuration 5 RS485 Data Signals 6 Offset Bias RS485 6...

Page 3: ...ester data Channel 3 RS232 data The MR 913D is designed to operate with the MT 913D or RT 913D video transmitter with bi directional data over one multimode fiber optic cable The MR 913D multiplexes u...

Page 4: ...n Fibertek PS 12D is supplied with this unit The negative side of the power input is directly connected to ground ANSI NFPA 70 Class 2 wiring is recommended POWER CONNECTION Power is supplied to the u...

Page 5: ...of the copper device is connected to the Data In of the MR 913D The plus terminal of the copper device is connected to the plus terminal of the MR 913D and the minus is connected to the minus The rev...

Page 6: ...devices to go into a high impedance Hi Z state This allows multiple transmitter devices to reside on the same wire pair The software must dictate a protocol that allows only one device to transmit at...

Page 7: ...indicator is provided to monitor the data coming in from the fiber through the MR 913D and out onto the electrical interface The intensity of this indicator will vary with input data patterns however...

Page 8: ...ts have been tampered with This warranty shall be construed in accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction over this contract EXCEPT FOR THE FOREGOING...

Reviews: