background image

 

2

INSTALLATION AND OPERATION INSTRUCTIONS 

 

INTRODUCTION 

 

Thank you for purchasing your American Fibertek MR-440 multimode four channel video 
receiver. Please take a few minutes to read these installation instructions in order to 
obtain the maximum performance from this product. 
 

FUNCTIONAL DESCRIPTION 

The MR-440 operates as half of a transmitter / receiver pair for the transmission of four 
simultaneous, real time, baseband NTSC, PAL, RS170, or RS343 video signals over a 
single multimode fiber optic cable. It is designed to operate with the MT-440 or RT-440 
four channel video transmitter.  
 
The MR-440 receiver converts a single optical input into a maximum of four video 
outputs. The 440 Series product is designed to operate over an optical loss budget 
range of 0 to 12 dB. The system’s fiber bandwidth should be a minimum of 150 MHz at 
1300 nm. For example, if the system fiber has a 600 MHz-km modal bandwidth 
specification, the 440 will operate over a distance up to 4 km. The MR-440 operates on 
50 um or 62.5 um multimode fiber. Refer to the data sheets for detailed performance 
specifications. 
 
This unit is contained in a compact and rugged extruded aluminum housing with internal 
dc voltage regulation. The detachable terminal block and LED indicators provide for easy 
installation and monitoring of video and power.  
 
The MR-440 is designed for mounting as a modular stand alone unit. For a rack 
mounted version please see the RR-440. 

 
INSTALLATION 

THE INSTALLATION OF THIS UNIT SHOULD BE MADE BY A QUALIFIED SERVICE 
PERSON(S) AND MUST CONFORM TO ALL LOCAL CODES. 
  
Mount the unit to a secure surface using #8 (3mm) hardware in four places. Mounting 
dimensions can be found on the connection diagram included with this manual. Be sure 
to allow sufficient room for the required minimum bend radius of the fiber cable used. 

 
POWER SOURCE 

Power to the unit must be within the specifications listed. A 24VAC center tap 
transformer rated at 10VA is required. In the USA and in Canada an American Fibertek 
PS-24CT-T is supplied with this unit. 

 
POWER CONNECTION 

Power is supplied to the unit via a three pin Phoenix connector. The ground wire from 
the center tap supply must be connected to the center pin of the Phoenix connector. 
When installed properly, the voltage measured from the center pin to either of the 
outside pins will be 12 volts AC and voltage measured from one outside pin to the other 
outside pin will be 24 volts AC. 

INPUT / OUTPUT CONNECTIONS 

The fiber optic connection is made via a ST connector located on the left side of the unit. 