8.Up Link Socket
8.EMI/RFI Power Line Filter
EMI/RFI( Picture of the circuit diagram of the Power Line Filter)
(Input Loss)
( Reference of the waveform for the EMI / RFI )
Before
After
(Picture of the Power Line Filter)
9. Down Link Socket
10. Switch of the three phase
11. Standard voltage settings
12. Overload Voltage Indicator and Alarm Nute Switch
13. Lighting Switch
14. Master switch
15. Programming key
16. Up Button
17. Down Button
18. Remote Control
19.Output Socket
When entering Into the system, plug the network cable, and it can be connected with the
equipment of the same model (AFPD-022). while, this operating key has been locked
The product is equipped with eight 20A filter, each output can be an effective anti-electromagnetic
interference (EMI)and radio frequency interference(RFI)
1.Reduce the harassment of the voltage grid launched
2.Enhance the immunity and stop the impact from the unclean power supply.
When entering Into the system, plug the network cable, and it can be connected with the other
equipment of the same model . while, this operating key of the AFPD-022 which is connected with
is block has been locked
There are three choice for the Phase voltage from left to right :L1,L2,L3.
select one phase, the phase voltage will appear in the screen .
Before operating the AFPD-022, you have to set a standard for the voltage according to your
present voltage ,then the Alarm function will work under this standard .
When this red light flashes, it indicates that the voltage being connected has overpassed the
standard by 10% . Now, you should take your system into account and see if it can accept such a
voltage.
If you want to turn off the USB lamp, you could turn off this switch directly .
After connecting the equipment and setting the specification well, you could switch the equipment
on and off directly .
Press this key to edit or set up password to this equipment
Press this key to delay or set up password to this equipment
Press this key to shorten the running time for this equipment or cancel the password.
Only press this button and you will be able to control the switch for this equipment wherever and
whenever you are .
Use the generic socket that is appropriate internationally in the US-EU countries, allowing the
maximum load current of 13A or audio linear load 26A. Then load a pair of audio output jack that
does not exceed 40A, a phase output of not more than 64A, then a pair of purely resistance load
socket output does not exceed 20A, a phase output of not more than 32A
L1=L2=2×0.4mH
Cx=0.1μF
R=1.5MΩ
L1
L2
Cx
Cx
Cx
R
L
IN
E
L
O
A
D
CM
DM
10KHz
30M
d
B
100
90
80
70
60
50
40
30
20
10
0
100KHz
1MHz
10MHz
D
BμA
-
40
-
30
-
20
-
10
-
0
10
20
30
40
50
60
70
80
90
100
10.0KHZ
100KHZ
1
.
0MHZ
10MHZ
50MHZ
20
D
BμA
-
40
-
30
-
20
-
10
-
0
10
20
30
40
50
60
70
80
90
100
10.0KHZ
100KHZ
1
.
0MHZ
10MHZ
50MHZ
20
Summary of Contents for AFPD-022
Page 2: ......