AFFA AFPD-022 Operating Instructions Manual Download Page 8

5

6

8.Up Link Socket

8.EMI/RFI Power Line Filter

EMI/RFI( Picture of the circuit diagram of the Power Line Filter)

(Input Loss)

( Reference of the waveform for the EMI / RFI )

Before

After

(Picture of the Power Line Filter)

9. Down Link Socket

10. Switch of the three phase

11. Standard voltage settings

12. Overload Voltage Indicator and Alarm Nute Switch

13. Lighting Switch

14. Master switch

15.  Programming key

16. Up Button

17. Down Button

18. Remote Control

19.Output Socket

When entering Into the system, plug the network cable, and it can be connected with the 
equipment of the same model (AFPD-022). while, this operating key has been locked 

The product is equipped with eight 20A filter, each output can be an effective anti-electromagnetic 
interference (EMI)and radio frequency interference(RFI)
1.Reduce the harassment of the voltage grid launched
2.Enhance the immunity and stop the impact from the unclean power supply.

When entering Into the system, plug the network cable, and it can be connected with the other 
equipment of the same model . while, this operating key of the AFPD-022 which is connected with 
is block has been locked 

There are three choice for the Phase voltage from left to right :L1,L2,L3. 
select one phase, the phase voltage will appear in the screen .

Before operating the AFPD-022, you have to set a standard for the voltage according to your 
present voltage ,then the Alarm function will work under this standard .

When this red light flashes, it indicates that the voltage being connected has overpassed the 
standard by 10% . Now, you should take your system into account and see if it can accept such a 
voltage.

If you want to turn off the USB lamp, you could turn off this switch directly .

After connecting the equipment and setting the specification well, you could switch the equipment 
on and off directly .

Press this key to edit or set up password to this equipment

Press this key to delay or set up password to this equipment 

Press this key to shorten the running time for this equipment or cancel the password.

Only press this button and you will be able to control the switch for this equipment wherever and 
whenever you are .

Use the generic socket that is appropriate internationally in the US-EU countries, allowing the 
maximum load current of 13A or audio linear load 26A. Then load a pair of audio output jack that 
does not exceed 40A, a phase output of not more than 64A, then a pair of purely resistance load 
socket output does not exceed 20A, a phase output of not more than 32A

L1=L2=2×0.4mH

Cx=0.1μF

R=1.5MΩ

L1

L2

Cx

Cx

Cx

R

L

IN

E

L

O

A

D

CM

DM

10KHz

30M

d

B

100

90
80
70
60
50
40
30
20
10

0

100KHz

1MHz

10MHz

D

BμA

-

40

-

30

-

20

-

10

-

0

10

20

30

40

50

60

70

80

90

100

10.0KHZ

100KHZ

1

.

0MHZ

10MHZ

50MHZ

20

D

BμA

-

40

-

30

-

20

-

10

-

0

10

20

30

40

50

60

70

80

90

100

10.0KHZ

100KHZ

1

.

0MHZ

10MHZ

50MHZ

20

Summary of Contents for AFPD-022

Page 1: ...AGE DISPLAY LAMP IN LINK OUT LINK REMOTE CONTROLLER 1 2 3 4 5 6 7 8 PROGRAM INQUIRE DISPLAY POWER L3 L1 L2 ON OFF MUTE OVER VOLTAGE ALARM INDICATOR L1 L2 L3 120V 250V 240V 230V 130V AFFA Electronics L...

Page 2: ......

Page 3: ...RE DISPLAY POWER L3 L1 L2 ON OFF MUTE OVER VOLTAGE ALARM INDICATOR L1 L2 L3 120V 250V 240V 230V 130V OFF ON UP P RINOQGURIA RM E O OFNF DOWN PASINSPWUOTRD PAMSOSDWIFOYRD PC AO SSNW FIO RR MD POWER VOL...

Page 4: ...arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to co...

Page 5: ...of power input is correct Please read the instruction carefully if there is any uncertainty please consult with the manufacturer Power filter Model AFPD 022 General introduction AFPD 022 is a Triphas...

Page 6: ...Now you enter into the Authentication The first lamp flashing 0 all the time and the change password button also flashing now you can change the original code one by one When the last number being in...

Page 7: ...e system is closed now please press the switch for 1 second it will be opened on time B Powered off punctually C When all the ways are opened please keep pressing the mother switch for 1 second and th...

Page 8: ...to set a standard for the voltage according to your present voltage then the Alarm function will work under this standard When this red light flashes it indicates that the voltage being connected has...

Reviews: