Maintenance and repair
Assembly instructions
EN
PEL20 I PEL20-SL I PDL30 I PDL40 I PDL40-HP
06.09.2021
Version 4.0 57–68
9.3.1 Overview of the maintenance points
Fig. 15
Maintenance portal axis (exemplary PDL40)
No. Maintenance point Maintenance work
Interval
System
[On/Off] Remarks
1
Portal axis
Cleaning and
checking
As required
[Off]
-
Clean the rotational axis with a dry, lint-free cloth.
- Do not spray the rotational axis with water, do not use
aggressive cleaning agents.
- Perform a visual inspection of the axis.
Check screws for tight fit.
2
Entire portal axis
check
As required
[On]
Acoustic check for unusual noise development (in case of
unusual displacement movements or hard knocks,
eliminate malfunction immediately).
3
Guides
visual check
Every year
[Off]
Check for damage
4
Guides and rotor
Clean and lubricate
Every year
[Off]
Clean guides and rotor with a slightly oily cloth
Lubrication of the guides. At all lubrication points, if
necessary, press in grease of type Klübersynth UH1 14-31
with a grease gun.
9.3.2 Lubrication of the linear guide
NOTICE
Risk of damage due to improper lubricants!
Do not use lubricants with additives such as MoS2, graphite or PTFE. These
lubricants can damage the linear guides!
Only use the lubricants recommended by Afag in the maintenance table
chapter 9.3.1 or equivalent lubricants!