![AES 603 SPARTAN Installation Instructions Manual Download Page 3](http://html1.mh-extra.com/html/aes/603-spartan/603-spartan_installation-instructions-manual_2863487003.webp)
P a g e
|
3
Site Survey
Before installing this system, you need to be sure that the range of the system will be sufficient.
The transmitter and speech unit can be powered up, call button pressed, and then check that the
handset will ring from all areas in which it will be used.
.
Tip:
For longer range installations, locate the handset close to the front of the property, near a
window if possible. Concrete walls can reduce the open-air range of 400 metres/yards by 30-50%
per wall.
Transmitter Unit in Detail
N
/O
N
/C
+
C
O
M
+
-
24v
OUT
12v
0v
N
/C
1
2
3
4
C
N
/O
Sol
IN
24v
DC IN
2
1
C
O
M
-
+
-
+
-
2
2
0
0
u
F
2
2
0
0
u
F
2
2
0
0
u
F
1000u
Surge protection
fuses.
F1=1A
F2=0.5A
Microphone
connections
Speaker
connections
Button connections (use
button 1 only on this model)
Code
button
Optional antenna port
for additional range
Optional battery
backup output socket
(12v 3Ah max lead
acid)
Optional solar input
(12v 60w max, 24v 30w
max)
Earth terminal.
Connect to earth rod
otherwise manufacturer
warranty will be void
Relay outputs.
Volt free.
24v ac 2 amp max load
Speech
panel
Walls causing weak signal
Up to 200m / yards